| 2022-02-25 11:26:51 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR EMAIL [email protected]. | | | | | | 1. FBC B 107.2.1. SUBMITTED PRODUCT APPROVAL FL16718-R8 | | | SELECTED SYSTEM R-32 IS A RECOVER APPLICATION; ROOF | | | RECOVERS REQUIRE DOCUMENTAL EVIDENCE THAT THE EXISTING | | | ROOF SYSTEM DO NOT HAVE CONDITIONS LISTED IN 706.3 OF | | | THE 2020 FBC EXISTING BUILDING. | | | 2. PROVIDE FIELD UPLIFT TESTING IN ACCORDANCE WITH | | | TESTING APPLICATION STANDARD TAS 124 AS REQUIRED BY | | | LIMITATIONS 5.6.3 OF PRODUCT APPROVAL FL16718. | | | 3. FBC EB 706.3(1) PROVIDE A SIGNED AND SEALED MOISTURE | | | REPORT PREPARED BY A FLORIDA REGISTERED DESIGN | | | PROFESSIONAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | | |
|