| Date |
Text |
| 2022-03-08 18:40:46 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW |
| | COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #21121068 |
| | |
| | 1-SURVEY/DRAINAGE PLAN SUBMITTED: |
| | A)SITE PLAN & BOUNDARY SURVEY SUBMITTED SHOW "PROPOSED |
| | RETAINING WALL" ON THE EAST SIDE. CLEARLY IDENTIFY |
| | LOCATION OF PROPOSED RETAINING WALL. AND, PROVIDE |
| | COMPLETE DETAILS/SPECIFICATIONS FOR THE RETAINING WALL |
| | CONSTRUCTION. SEC. 107.2.5 CITY AMENDMENTS. R401.3 |
| | FBC-RESIDENTIAL. |
| | |
| | B)A SEPARATE PERMIT WILL BE REQUIRED FOR THE |
| | CONSTRUCTION OF THE RETAINING WALL. SEC.105.1 CITY |
| | AMENDMENTS. |
| | |
| | 2- ENERGY CALCULATIONS SUBMITTED: |
| | A)ENERGY CALCULATIONS FORM R405-2020 IS REQUIRED TO BE |
| | CERTIFIED AT THE BOTTOM BY THE OWNER, THE OWNER'S |
| | ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY |
| | THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY |
| | SEC. R103.1.1.2 FBC-ENERGY CONSERVATION. |
| | |
| | B)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE |
| | LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY |
| | CONSERVATION. |
| | |
| | 3- WIND RESISTANCE OF EXTERIOR SOFFITS: |
| | TYPICAL WALL SECTION ON SHEET 3-4 ONLY SPECIFIES |
| | "METHAL LATH AND STUCCO SOFFIT W/ 7"X24" SCREENED VENTS |
| | @ 8'-0" O.C.". THERE ARE NO SPECIFICATIONS FOR |
| | SHEATHING TO SUPPORT THE METHAL LATH. ENGINEER OF |
| | RECORD TO PROVIDE CALCULATIONS SHOWING THAT THIS SOFFIT |
| | SPECIFICATIONS WITHOUT SHEATHING ARE ADEQUATE TO RESIST |
| | THE WIND LOADS AS REQUIRED BY SEC. R704 FBC-RESIDENTIAL |
| | OR REVISE DETAIL PROVIDING COMPLETE SHEATHING |
| | SPECIFICATIONS (MATERIAL, THICKNESS AND FASTENING). |
| | SEC. 107.2.1.2 CITY AMENDMENTS. SEC. R301.2.1 |
| | FBC-RESIDENTIAL. |
| | |
| | 4-PRODUCT APPROVALS |
| | PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 |
| | FOR |
| | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| | SUBMITTAL): |
| | |
| | A)REAR FRENCH DOOR AS SHOWN ON PLANS. |
| | |
| | 5-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVAL AS |
| | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | 6- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, |
| | CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN |
| | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY |
| | AMENDMENTS. VALUATION WAS UPDATED TO $256,270. THE |
| | PERMIT FEE BALANCE IS $1864.99. |
| | |
| | 7- CLARIFY WHY SUBMITTING PRODUCT APPROVALS FOR |
| | OVERHEAD GARAGE DOORS AND SLIDING GLASS DOORS. DRAWINGS |
| | DON'T SHOW ANY. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE |
| | REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | |