2021-12-30 11:35:54REVISION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) THE APEARANCE OF WALL TILE HAS BEEN REMOVED FROM
 DRAWING - A9.1.6 DETAIL 9 - PLEASE PROVIDE WALL FINISH
 DETAIL FBC 1210.2.2
  
 2) THE APEARANCE OF WALL TILE HAS BEEN REMOVED FROM
 DRAWING - A9.1.3 DETAIL 3 - PLEASE PROVIDE WALL FINISH
 DETAIL FBC 1210.2.2
  
 3) THE APEARANCE OF WALL TILE HAS BEEN REMOVED FROM
 DRAWING - A9.1.9 DETAIL 7 - PLEASE PROVIDE WALL FINISH
 DETAIL FBC 1210.2.2
  
 4) DRAWING A1.1.1B - COOLER DOORS ENCROACH ON THE MEANS
 OF EGRESS - PLEASE SHOW DIMENSIONS THAT COOLER DOORS
 WILL COMPLY WITH FBC 1005.7.1 DOORS.
 DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED
 WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY
 POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE
 THAN ONE-HALF.