| Date |
Text |
| 2021-12-27 13:21:56 | JONATHAN BROOKS JR. |
| | BUILDING PLANS EXAMINER |
| | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| | PHONE (561) 805-6656 |
| | EMAIL: [email protected] |
| | |
| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR EMAIL [email protected] AND REQUEST |
| | THAT IT BE CONVERTED TO PROJECTDOX. |
| | |
| | 1. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL |
| | FL1654-R28 IS INCOMPLETE, PROVIDE THE FOLLOWING |
| | ADDITIONAL INFORMATION: COVER SHEET |
| | (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE (CODE |
| | VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL |
| | INFORMATION ABOUT THE PRODUCT). SECOND REQUEST. |
| | 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT |
| | APPROVAL FL20378.01-R3 IS NOT RATED FOR USE IN ZONE 3 |
| | FOR STRUCTURES LOCATED IN EXPOSURE B, C OR D EXPOSURE |
| | AREA HAVE EITHER FLAT ROOF, GABLE/HIP ROOF WITH MAX |
| | SLOPE OF 12:12 WITH A MEAN ROOF HEIGHT 30 FEET OR LESS |
| | WIND SPEED 170 MPH. PROVIDE SIGNED AND SEALED |
| | ENGINEERING FOR USE OR SELECT A SYSTEM THAT MEETS THE |
| | ABOVE CRITERIA. PROJECT LOCATED IN EXPOSURE C CATEGORY |
| | AREA. SECOND REQUEST. |
| | 3. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R33 |
| | SELECTED PRODUCT POLYSTIC IR-XE IS NOT APPROVED FOR USE |
| | IN A METAL ROOF SYSTEM AS PER LIMITATIONS #5.6. SELECT |
| | A PRODUCT THAT IS APPROVED FOR USE IN A METAL ROOF |
| | SYSTEM. SECOND REQUEST. |
| | 4. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF |
| | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW |
| | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD |
| | OF PROVIDING POSITIVE DRAINAGE. SECOND REQUEST. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. |
| | |