| 2022-06-23 06:19:11 | 3RD PLUMBING REVIEW | | | | | | PLAN REVIEW RESULTS: DENIED | | | | | | 1. 2020 FRC P3101.2.1 VENTING REQUIRED. -- THE LAUNDRY | | | TRAP IS NOT VENTED IN ACCORDANCE WITH THE CODE. PLEASE | | | SHOW A COMPLIANT VENT FOR THE LAUNDRY FIXTURE DRAIN. | | | | | | THE "FIXTURE DRAIN" ITSELF NEEDS A VENT BEFORE IT | | | CONNECTS TO THE STACK. YOU WOULD NEED TO CONNECT A VENT | | | SOMEWHERE BETWEEN THE TRAP AND THE STACK. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | |
|