| Date |
Text |
| 2021-12-14 13:36:32 | JONATHAN BROOKS JR. |
| | BUILDING PLANS EXAMINER |
| | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| | PHONE (561) 805-6656 |
| | EMAIL: [email protected] |
| | |
| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR EMAIL [email protected] AND REQUEST |
| | THAT IT BE CONVERTED TO PROJECTDOX. |
| | |
| | 1. FBC B 107.2.1. PROVIDE THE FOLLOWING INFORMATION FOR |
| | FLORIDA DBPR PRODUCT APPROVAL FL11475-R11 THE PROPOSED |
| | FLAT ROOF SYSTEM TO BE USED. COVER PAGE, EVALUATION |
| | REPORTS TO INCLUDE LIMITATIONS PAGE(S) AND INSTALLATION |
| | INSTRUCTIONS FOR SYSTEM USED. ALL APPLICABLE DETAILS |
| | AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE |
| | PRODUCT APPROVAL DRAWINGS. |
| | 2. PROVIDE FIELD UPLIFT TESTING IN ACCORDANCE WITH |
| | TESTING APPLICATION STANDARD TAS 124 AS REQUIRED BY |
| | LIMITATIONS 5.6.1 OF PRODUCT APPROVAL FL11475-R11. |
| | 3. FBC B 1609 PROVIDE A COMPLETE SET OF SIGNED AND |
| | SEALED ENGINEERED DESIGN PRESSURE CALCULATIONS BY A |
| | FLORIDA REGISTERED PROFESSIONAL ENGINEER, REGISTERED |
| | ARCHITECT, OR REGISTERED ROOF CONSULTANT. |
| | 4. FBC EB 706.6 PROVIDE A FLASHING DETAIL FOR THE |
| | EXISTING PARAPET WALLS TO INCLUDE PARAPET WALL |
| | HEIGHT(S). |
| | 5. FBC B 107.2.1 PROVIDE A SIGN AND SEALED ROOF |
| | DRAINAGE PLAN THAT COMPLIES WITH SECTION 1503 OF THE |
| | 2020 FBC-BUILDING AND CHAPTER 11 OF THE 2020 |
| | FBC-PLUMBING. |
| | 6. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF |
| | DIAGRAM/SKETCH AND SHOW THE AREAS TO RECEIVE NEW |
| | ROOFING CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF |
| | SLOPE(S), ROOF HEIGHT(S). |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. |
| | |