| Date |
Text |
| 2021-12-16 09:50:57 | JONATHAN BROOKS JR. |
| | BUILDING PLANS EXAMINER |
| | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| | PHONE (561) 805-6656 |
| | EMAIL: [email protected] |
| | |
| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR EMAIL [email protected] AND REQUEST |
| | THAT IT BE CONVERTED TO PROJECTDOX. |
| | |
| | 1. FBC EB 706.3(1) PROVIDE A SIGNED AND SEALED MOISTURE |
| | REPORT PREPARED BY A FLORIDA REGISTERED DESIGN |
| | PROFESSIONAL. |
| | 2. FBC B 107.2.1 PROVIDE A BRIEF DESCRIPTION OF THE |
| | CONSTRUCTION METHODS TO BE USED TO MAKE ROOF REPAIRS TO |
| | INCLUDE MATERIALS USED. |
| | 3. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF |
| | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW |
| | REPAIR/COATING CLEARLY IDENTIFIED ON DRAWING; INCLUDE |
| | ROOF SLOPE(S), MEAN ROOF HEIGHT(S) TOTAL SQUARE FOOTAGE |
| | OF ROOF AREA/SECTION, TOTAL SQUARE FOOTAGE OF ROOF AREA |
| | TO BE REPAIRED/COATED. PLEASE NOTE: FBC EB 706.1. NOT |
| | MORE THAN 25 PERCENT OF THE TOTAL ROOF AREA OR ROOF |
| | SECTION OF ANY EXISTING BUILDING OR STRUCTURE SHALL BE |
| | REPAIRED, REPLACED OR RECOVERED IN ANY 12-MONTH PERIOD |
| | UNLESS THE ENTIRE ROOFING SYSTEM OR ROOF SECTION IS |
| | REPLACED TO CONFORM TO THIS CODE. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. |
| | |