| Plan Review Notes For Permit 21120296 |
| Permit Number |
21120296 |
|
| Review Stop |
B |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2022-03-23 15:54:10 | BUILDING PLAN REVIEW | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | 3RD REVIEW | | | | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PRESSURE TREATED WOOD SHALL COMPLY WITH FBC | | | R402.1.2. | | | R402.1.2WOOD TREATMENT. | | | ALL LUMBER AND PLYWOOD SHALL BE PRESSURE-PRESERVATIVE | | | TREATED AND DRIED AFTER TREATMENT IN ACCORDANCE WITH | | | AWPA U1 (COMMODITY SPECIFICATION A, SPECIAL REQUIREMENT | | | 4.2) AND SHALL BEAR THE LABEL OF AN ACCREDITED AGENCY. | | | WHERE LUMBER AND/OR PLYWOOD IS CUT OR DRILLED AFTER | | | TREATMENT, THE TREATED SURFACE SHALL BE FIELD TREATED | | | WITH COPPER NAPHTHENATE, THE CONCENTRATION OF WHICH | | | SHALL CONTAIN A MINIMUM OF 2-PERCENT COPPER METAL, BY | | | REPEATED BRUSHING, DIPPING OR SOAKING UNTIL THE WOOD | | | ABSORBS NO MORE PRESERVATIVE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|