| Date |
Text |
| 2022-01-04 14:25:26 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| | SERVICES/ BUILDING DIVISION |
| | 2020 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 21120201 |
| | ADD: 901 N. SAPODILLA AVE. |
| | CONT: TBD/ TO BE DETERMINED OWNER: EDUARDO J. GUTIERREZ |
| | TEL: 561-856-4417 |
| | E-MAIL: [email protected] |
| | |
| | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. JAN. 04TH/ 2022 |
| | ACTION: DENIED |
| | |
| | 1A) IT IS NOT CLEAR AS TO WHAT IS TO OCCUR WITH THIS |
| | PERMIT. THE PERMIT APPLICATION UNDER THE HEADING OF |
| | DISCERPTION OF WORK: CHANGE OF OCCUPANCY FROM |
| | COMMERCIAL TO RESIDENTIAL PROPERTY. THE SUBMITTED FLOOR |
| | PLAN FROM CORNER STONE C. & D. CORP STATES THE FLOOR |
| | PLAN IS FOR MULTIFAMILY REMODELING. THE QUESTION IS ARE |
| | YOU TRYING TO TURN A 3 UNIT APARTMENT BUILDING INTO A |
| | SINGLE FAMILY DWELLING? OR A ONE- AND TWO-FAMILY |
| | DWELLING? PALM BEACH COUNTY PROPERTY APPRAISERS OFFICE |
| | SHOWS THIS PROPERTY TO HAVE HOMESTEAD EXEMPTION FOR |
| | 2022. SUBMIT FLOOR PLAN OF EXISTING CONDITIONS AND |
| | PROPOSED CHANGES PROPOSED FLOOR PLAN. |
| | |
| | 1B) IF THIS PERMIT IS TO BE A 1 AND 2 FAMILY DWELLING |
| | AND THE OWNER IS TO ACT AS THE CONTRACTOR, THEN THEY |
| | MUST SIGN THE OWNWE/ BUILDER DISCLOSURE STATEMENT, AND |
| | ABIDE BY THE NOT BEING ABLE TO RENT OR SEEL THE |
| | PROPERTY FOR ONE YEAR AFTER A CERTIFICATE OF COMPLETION |
| | IS ISSUED. |
| | |
| | 2) PLEASE NOTE AS THE NEW OWNER YOU INHERIT WORK THAT |
| | WAS COMPLETED WITHOUT PERMIT. IN 2009 THERE WAS A BOARD |
| | AND SECURE PERMIT ISSUED TO BOARD UP THE BUILDING. A |
| | TENANT BROKE OUT ALL OF THE GLASS FROM ALL WINDOWS. |
| | USING GOOGLE STREET SCAPE, IT APPEARS NOT ONLY NEW |
| | GLAZING IN THE EXISTING WINDOWS, BUT NEW WINDOWS AND |
| | DOORS WERE INSTALLED WITHOUT PERMIT. THE WINDOW |
| | OPENINGS SHOW NEW STUCCO AROUND ALL WINDOWS. SUPPLY |
| | WINDOW SCHEDULE SHOWING NEW WINDOWS, PRODUCT APPROVAL |
| | FOR ALL WINDOWS, IF THEY ARE LARGE MISSILE RESISTANT |
| | AND OR IF NON-IMPACT GLAZING THEN SHUTTERS IN |
| | COMPLIANCE WITH THE EITHER RESIDENTIAL CODE OR THE |
| | BUILDING CODE DEPENDING ON THE OCCUPANCY TYPE. |
| | R2 3 APARTMENTS 2020 FBC-BUILDING CODE |
| | R3 1 AND 2 FAMILY 2020 FBC-RESIDENTIAL CODE |
| | |
| | 2A) COMPONENTS & CLADDING. PLEASE SUBMIT THE COMPONENTS |
| | AND CLADDING PRODUCT APPROVALS. 2020 FBC-B 1609.1.2 |
| | PROTECTION OF OPENINGS, 1609.6.4.4.1 COMPONENTS & |
| | CLADDING. FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, |
| | ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 NOV. 01/ |
| | 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION |
| | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: |
| | (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES. |
| | (B) WINDOWS & MULLIONS |
| | |
| | 2B) IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY IN THE |
| | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF |
| | RECORD AND BEFORE SUBMISSION TO THE BUILDING |
| | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE |
| | IDENTIFY THE OPENING WIDTH & HEIGHT, SILL HEIGTH, TYPE |
| | OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED OR |
| | REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND |
| | ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B |
| | 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE |
| | INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S |
| | INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE |
| | PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED |
| | BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS. |
| | 2C) STORM SHUTTERS. REQUIRED IF NON-IMPACT WINDOW UNITS |
| | WERE INSTALLED. PROVIDE STORM PANEL INFORMATION WITH |
| | INSTALLATION SCHEDULE AND KEY PLAN WITH SPECIFIC |
| | ANCHORS AND MOUNTING TO BE USED FOR ALL NON-IMPACT |
| | GLAZING. FBC 1609.1.2. |
| | FL BLD CODE 2010 SECTION 107.2.5.,1609.1.2, 1715.8 & |
| | EXIST BUILD CODE 706.4 PROCEDURES: A COMPLETE |
| | INSTALLATION SCHEDULE SUMMARIZING & IDENTIFYING OPENING |
| | SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT |
| | SPANS/WIDTHS, UNIT STORM BAR REINFORCING REQUIREMENTS, |
| | WALL PRESSURE ZONES, SLAT TYPES, ETC. |
| | 2D) THE FLOOR PLAN IS MISSING THE WEST ELEVATION, |
| | PLEASE ALSO PROVIDE ON THE FLOOR PLAN THE DISTANCE FROM |
| | THE WEST EXTERIOR WALL LINE TO THE PROPERTY LINE. |
| | |
| | 3) 2020 W. P. B. ADMINISTRATIVE CODE107.3.5 MINIMUM |
| | PLAN REVIEW CRITERIA |
| | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATIVE CODE SECTION: |
| | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS AND |
| | OR STRUCTURES. |
| | 107.3.5.1 COMMERCIAL BUILDINGS |
| | 107.3.5.1.1. BUILDING |
| | |
| | MISSING CODE DATA: |
| | SITE REQUIREMENTS: |
| | PARKING |
| | SET BACK/ SEPARATION (ASSUMED PROPERTY LINES |
| | LOCATION OF SEWERS, WATER LINES AND SEWER LINES |
| | OCCUPANCY GROUP |
| | MINIMUM TYPE OF CONSTRUCTION |
| | FIRE RESISTANCE SEPARATION |
| | LIFE SAFETY PLANS SHALL DETERMINE AND SHALL INCLUDE THE |
| | FOLLOWING: |
| | CODE DATA/ BUILDING DATA |
| | OCCUPANT LOAD AND EGRESS CAPACITIES |
| | GROSS OR NET |
| | MEANS OF EGRESS EXIT ACCESS |
| | |
| | 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| | REVIEW CYCLE. |
| | |
| | |
| | AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING |
| | FROM CITY HALL. |
| | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM |
| | PART-TIME/ RETIRED. |
| | |
| | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET |
| | BACK INTO THE OFFICE CALL |
| | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. |
| | THANK YOU. |
| | |
| | JAMES A. WITMER BN, PX, SFP, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6717 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |