| 2022-06-21 11:41:48 | 1ST REVIEW FBC-2020 RES. |
| | PERMIT- 21111282 |
| | 6/21/22 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN FOR THE |
| | GRILL THAT INDICATES THE MAKE AND MODEL NUMBER, NATURAL |
| | OR LP GAS FIRED, AND THE BTU LOAD OF THE APPLIANCE- |
| | G2408.1 & G2447.1 FBC RES. A) FOR NATURAL GAS |
| | INSTALLATIONS PLEASE CLARIFY IF NEW GAS PIPING IS BEING |
| | INSTALLED TO SUPPLY THE GRILL. OR IF THERE IS AN |
| | EXISTING PIPE THROUGH THE WALL BEHIND THE GRILL. PLEASE |
| | PROVIDE THE TYPE, SIZE, AND SUPPLY PRESSURE OF THE |
| | EXISTING PIPE IF APPLICABLE, OR PROVIDE A COMPLETE GAS |
| | RISER FOR NEW INSTALLATIONS- SEC. 107.2.1 & 107.3.5.3 |
| | WPB. |
| | |
| | 2) REFER TO THE MANUFACTURER'S SPECIFICATIONS AND SHOW |
| | THE LOCATIONS AND SIZES OF COMBUSTION AIR AND |
| | VENTILATION OPENINGS- SEC. G2407.1 FBC RES. |
| | |
| | 3) PLEASE PROVIDE ON THE SURVEY OR ON A SITE PLAN THE |
| | EXACT LOCATION OF THE GRILL. PLEASE NOTE THAT MANY OF |
| | THE GRILL MANUFACTURER'S DO NOT ALLOW INSTALLATIONS IN |
| | ENCLOSED OR PARTIALLY ENCLOSED STRUCTURES WITH OVERHEAD |
| | CONSTRUCTION UNLESS A HOOD AND EXHAUST VENT SYSTEM IS |
| | INSTALLED- G2408.1 & G2447.1 FBC RES. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |