| Date |
Text |
| 2022-02-24 18:21:18 | RESIDENTIAL (R3) ALTERATION/ADDITION SECOND BUILDING |
| | REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #21111240. |
| | |
| | |
| | NOTE: |
| | BUILDING REVIEW MAY BE APPROVED WITH PROVISO. PROVISO |
| | MEANS CONTRACTOR WILL SUBMIT REQUIRED INFORMATION AFTER |
| | THE PERMIT IS ISSUED BUT BEFORE INSPECTIONS TO AVOID |
| | CONFLICTS/DELAYS. REVISION FEES MAY APPLY. CONTRACTOR |
| | TO ADVICE IF PROVISO OPTION IS PREFERRED AT THIS TIME |
| | OR IF RE-SUBMITTING REQUIRED INFORMATION BEFORE PERMIT |
| | ISSUANCE. |
| | |
| | |
| | 1- OK. |
| | 2- OK. |
| | |
| | ORIGINAL COMMENT: |
| | 3-LOW SLOPE ROOFS: PROVIDE COMPLETE DETAILS AND |
| | SPECIFICATIONS FOR OVERFLOW DRAINS OR SCUPPERS AS |
| | REQUIRED BY SEC. R903.4.1 FBC-RESIDENTIAL. |
| | PROVIDE DETAILS: SPECIFY SIZE AND LOCATION ON ROOF. |
| | |
| | RESPONSE: |
| | ROOF PLAN DOESN'T SHOW LOCATION OF THE OVERFLOW |
| | SCUPPERS. ALSO, THERE IS A NOTE STATING "PROVIDE |
| | OPENING IN PARAPET FOR SCUPPER TO LEADER TO STORM WATER |
| | CONTROL SYSTEM DESIGN BY OTHERS. FLASH PER DETAILS ON |
| | A-3 SHEET & MANUFACTURER'S SPECIFICATIONS. (TYP EA |
| | SIDE)". PROVIDE COMPLETE STORM WATER CONTROL SYSTEM |
| | DESIGN FOR THIS SINGLE FAMILY RESIDENCE. SEC.107.2.1 |
| | CITY AMENDMENTS. |
| | |
| | 4- PRESSURE ZONES DETAIL 4 ON SHEET A-1: |
| | A)OK. |
| | |
| | ORIGINAL COMMENT: |
| | B)CLARIFY ROOF DIAGRAM ROOF ZONES. SPECIFY WHAT IS THE |
| | DIMENSION FOR "A". SEE FIGURE R301.2(7) |
| | FBC-RESIDENTIAL. CLARIFY WHY DESIGN PRESSURES FOR ZONE |
| | 3' ARE LOWER THAN DESIGN PRESSURES FOR ZONE 3 IF IT |
| | LOOKS LIKE ROOF ZONE IS THE OUTER CORNER. ALSO, WHERE |
| | ARE ROOF ZONES 3' AND 3 COMING FROM?. SEC. R301.2.1 |
| | FBC-RESIDENTIAL. SEC. 107.2.1.2 CITY AMENDMENTS. |
| | |
| | RESPONSE: |
| | REVISED FLAT ROOF DIAGRAM DOESN'T MATCH NEW ROOF |
| | DIAGRAM SHOWN ON THE CURRENT 2020 RESIDENTIAL CODE. SEE |
| | FIGURE R301.2(7) AND REVISE AS REQUIRED. |
| | |
| | 5- OK. |
| | 6- OK. |
| | 7- OK. |
| | |
| | NEW COMMENT BASED ON REVISED WIND CALCULATIONS: |
| | 8- THE DESIGN PRESSURES OF GARAGE DOOR NOA 20-0922.55 |
| | DON'T MEET THE DESIGN PRESSURES CALCULATED BY THE |
| | ARCHITECT ON THE REVISED COMPONENTS AND CLADDING |
| | CALCULATIONS. NEED TO SUBMIT PRODUCT APPROVAL THAT |
| | MEETS OR EXCEEDS THE REVISED DESIGN CALCULATIONS. FAC |
| | 61G20.3.001. |
| | |
| | 9-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ABOVE REVISED PRODUCT |
| | APPROVAL AS REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |