| Plan Review Notes For Permit 21111047 |
| Permit Number |
21111047 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2022-01-14 17:44:23 | RESIDENTIAL(R3) FENCE BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #21111047. | | | | | | 1- PERMIT APPLICATION, SURVEY AND DETAILS SUBMITTED | | | ONLY SHOW INSTALLATION OF (1)16X4 ROLL GATE, (1)13X4 | | | ROLL GATE AND (1)3X4 ALUM. GATE. THERE IS NO FENCE IN | | | THIS AREA. SURVEY SHOWS FREE STANDING ROLLING GATES. | | | THERE IS NO INFORMATION SHOWING HOW THE ROLLING GATES | | | ARE GOING TO BE FASTENED. PROVIDE COMPLETE | | | DETAILS/SPECIFICATIONS FOR ROLLING GATES FASTENING. | | | SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 2- THERE IS A POOL IN THIS PROPERTY. ACCESS GATE NEEDS | | | TO COMPLY WITH POOL CHILD BARRIER REQUIREMENTS. | | | SEC. R4501.17.1.8 FBC-RESIDENTIAL. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|