| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR EMAIL [email protected] AND REQUEST |
| | THAT IT BE CONVERTED TO PROJECTDOX. |
| | |
| | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT |
| | APPROVAL FL2533-R26 SELECTED SYSTEM NO. R-25 DO NOT |
| | MEET THE EXPOSURE CATEGORY C; ZONE 3 MINIMUM DESIGN |
| | PRESSURE REQUIREMENT OF -108.17. PLEASE SELECT SYSTEM |
| | NO. THAT MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE |
| | SIGNED AND SEALED ENGINEERED NAILING CALCULATION FOR |
| | ZONE 3. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE |
| | CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. |
| | DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN |
| | PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. |
| | 2. FBC EB 706.3(1) PROVIDE A SIGNED AND SEALED MOISTURE |
| | REPORT PREPARED BY A FLORIDA REGISTERED DESIGN |
| | PROFESSIONAL. |
| | 3. PROVIDE FIELD UPLIFT TESTING IN ACCORDANCE WITH |
| | TESTING APPLICATION STANDARD TAS 124 AS REQUIRED BY |
| | LIMITATIONS 5.6.3 OF PRODUCT APPROVAL FL2533-R26. |
| | 4. FBC B 107.2.1 PROVIDE A SIGN AND SEALED ROOF |
| | DRAINAGE PLAN THAT COMPLIES WITH SECTION 1503 OF THE |
| | 2020 FBC-BUILDING AND CHAPTER 11 OF THE 2020 |
| | FBC-PLUMBING. |
| | 5. FBC EB 706.6 PROVIDE A FLASHING DETAIL FOR THE |
| | EXISTING PARAPET WALLS TO INCLUDE PARAPET WALL |
| | HEIGHT(S). |
| | 6. FBC R 301 FAC9N-3. PROVIDE A COMPLETE SET OF 2020 |
| | CODE VERSION PRODUCT APPROVALS/NOA'S FOR THE PROPOSED |
| | HIP & RIDGE METAL TO BE USED. |
| | 7. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF |
| | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING |
| | CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), |
| | MEAN ROOF HEIGHT(S). |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. |
| | |