Plan Review Notes
Plan Review Notes For Permit 21110915
Permit Number 21110915
Review Stop G
Sequence Number 1
Notes
Date Text
2021-12-02 13:02:171ST REVIEW FBC-2020 RES.
 PERMIT-21110915
 12/2/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
 PLAN REVIEW RESULTS: DENIED.
  
 1) SUBMIT MANUFACTURER?S SPECIFICATIONS AND INSTALL
 MANUALS FOR THE TANKLESS WATER HEATERS, AND THE RANGE-
 SECTIONS G2448.1, G2447.1 FBC RES.
  
 2) PROVIDE COMBUSTION AIR CALCULATIONS FOR THE RANGE
 AND INDICATE HOW THE AIR WILL BE PROVIDED- G2407.1.
  
 3) PLEASE NOTE THAT A SEPARATE PERMIT IS REQUIRED FOR
 INSTALLATION OF THE POOL HEATER. PLEASE PLACE A NOTE
 THAT THE POOL HEATER IS ?FUTURE? AND PROVIDE A
 GAS-TIGHT CAP AT THE LOCATION- G2415.15.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  