Plan Review Notes
Plan Review Notes For Permit 21110872
Permit Number 21110872
Review Stop G
Sequence Number 2
Notes
Date Text
2022-04-05 09:27:38GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN
 THIS SUBMITTAL PACKAGE, AND A GAS PLAN REVIEW HAS NOT
 BEEN PERFORMED AT THIS TIME. PROVIDE COMPLETE PLANS AND
 GAS RISER THAT REFLECTS THE ENTIRE SCOPE OF GAS WORK TO
 BE DONE PER THE WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 A SUB GAS PERMIT IS ON FILE BUT NO GAS INFORMATION HAS
 BEEN SUBMITTED.
  
 A ISOMETRIC IS REQUIRED FOR GAS ISOMETRIC, ALL
 APPLIANCES, IF OTHER APPLIANCES ARE IN THE SYSTEM SHOW
 THEM, MANUFACTURE SPECIFICATION FOR EQUIPMENT AND
 REGULATOR, TYPE OF GAS, TOTAL BTU'S, LONGEST RUN,
 TABLES USED, PRESSURE OF GAS, SHOW AND LABEL SHUT OFF
 VALVE, UNIONS, REGULATORS AND DRIP LEGS IF USED.
  
  