| 2021-11-22 08:30:04 | 11/22/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS |
| | |
| | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS |
| | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE |
| | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. |
| | |
| | |
| | 1. A SKETCH WAS SUBMITTED FOR EXISTING DEMO WORK, AND |
| | THE FOLLOWING NEED CLARIFICATION PER THE WPB AMENDMENTS |
| | TO THE FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION |
| | DOCUMENTS; |
| | |
| | A. THERE SEEMS TO BE A RESTROOM CROSSED OUT, AND NOT |
| | THAT IS NOT SHOWN ON S-1.0. IS IT BEING REMOVED, AND IF |
| | SO, PLEASE MENTION THE SCOPE OF WORK FOR S-1.0. |
| | |
| | B. THE IS A SET OF CABINET DRAWINGS AND NO REFERENCE TO |
| | WHERE GO ON S-1.0. |
| | |
| | C. THERE IS A STORAGE TANK TYPE BEING CHANGED TO A |
| | TANK-LESS. WOULD YOU PLEASE PROVIDE THE MANUFACTURE |
| | SPECIFICATIONS? |
| | |
| | D. IS THE TANK-LESS ELECTRIC OR GAS, AND IT IS NOT ON |
| | THE E-1.0 SHEET IF IT IS ELECTRIC. IF THIS TANK-LESS IS |
| | UNDER A SEPARATE PERMIT WOULD YOU, PLEASE NOTE THAT ON |
| | PLANS. |
| | |
| | E. THE SIGNATURE ON THE DRAWING OF THE PERSON TAKING |
| | RESPONSIBILITY FOR THE DRAWING DOES NOT HAVE THE NAME |
| | PRINTED OR WHAT IS CAPACITY IS (OWNER/ |
| | CONTRACTOR>LICENSED REQUIRED), WHICH IS NOT IN |
| | ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE |
| | 61G15-23.001, FLORIDA STATUTE 471 PER THE WPB |
| | AMENDMENTS TO THE FBC SEC. 107.1 GENERAL. |
| | |
| | F. THE PHYSICAL ADDRESS OF THE RESIDENCE MUST BE ON |
| | PLANS IN FULL, NUMBER, STREET, CITY, STATE, AND ZIP |
| | CODE PER THE WPB AMENDMENTS TO THE FBC SEC.107.2.1 |
| | INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | |
| | G. THE DRAWING IS VERY LIGHT AND HARD TO READ PORTIONS |
| | OF IT. |
| | |
| | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & |
| | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA |
| | |
| | LUIS A. CRESPO |
| | PLUMBING PLAN EXAMINER / INSPECTOR |
| | EMAIL: [email protected] OFFICE: 561 805-6720 |
| | |