| Date |
Text |
| 2021-12-03 12:05:46 | 1ST REVIEW FBC-2020 RES. FUEL GAS |
| | PERMIT- 21110757 |
| | 12/03/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| | 2020 |
| | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) WPB BUILDING DEPARTMENT RECORDS SHOW AN EXISTING 622 |
| | MBTU LOW PRESSURE GAS PIPING SYSTEM WAS APPROVED UNDER |
| | PERMIT- 04090823. THE SYSTEM SERVES MULTIPLE APPLIANCES |
| | INCLUDING A SPA HEATER, WATER HEATER, RANGE, GRILL, AND |
| | DRYER. PROVIDE A COMPLETE GAS RISER DRAWING THAT |
| | INCLUDES ALL NEW AND EXISTING GAS PIPING AND APPLIANCES |
| | AT THE RESIDENCE- SECTION G2412.3 & G2412.4 FBC RES. |
| | REFER TO FBC RES. CHAPTER 24 FUEL GAS- THE RISER SHALL |
| | INDICATE: |
| | A) TYPE OF GAS- NATURAL OR LP. |
| | B) DELIVERY PRESSURE AT THE METER. |
| | C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. |
| | D) TYPES AND SIZES OF PIPING. |
| | E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER |
| | TO THE MOST REMOTE APPLIANCE OUTLET. |
| | F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. |
| | G) LOCATIONS OF REGULATORS, SHUTOFF VALVES, AND PIPE |
| | UNIONS. |
| | H) OUTLET PRESSURES AT REGULATORS. |
| | I) LOCATIONS AND TYPES OF PIPE SLEEVES. |
| | K) PIPE SIZING TABLES. |
| | |
| | 2) SUBMIT THE MANUFACTURER?S SPECIFICATIONS FOR THE |
| | RANGE THAR INCLUDE THE APPLIANCE LISTING, BTU CAPACITY, |
| | AND INPUT PRESSURE- SECTION G2447.1 FBC RES. |
| | |
| | 3) THE $550.00 VALUE APPEARS LOW FOR THE SCOPE OF WORK |
| | INCLUDING THE COSRT OF THE NEW RANGE. PLEASE PROVIDE A |
| | VALUE THAT INCLUDES THE COSTS OF LABOR, MATERIALS, |
| | EQUIPMENT, AND THE NEW RANGE- SECTION 109.3 WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |
| | |