| Date |
Text |
| 2022-03-30 16:52:35 | RESTAURANT ADDITION |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) PLEASE SHOW ON THE DRAWINGS IF BUILDING IS |
| | SPRINKLERED OR NON-SPRINKLERED FBC CHAPTER 5 |
| | |
| | 2) PLEASE SHOW THE DIMENSION FROM THE BOTTOM OF THE |
| | OVERFLOW SCUPPER TO THE ROOF DECK - 1503.4.2.1 OVERFLOW |
| | SCUPPERS. |
| | WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT |
| | PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR |
| | PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4 |
| | INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND |
| | SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED |
| | VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET |
| | SCUPPERS. |
| | |
| | 3) DRAWING A.800 - DIMENSION TO THE BOTTOM OF THE |
| | MIRROR SHOULD SAY - 40" MAX. (NOT 40" MIN.). FBC A |
| | 603.3 |
| | |
| | 4) THE EXISTING BUILDING FLOOR IS BEING RAISED - PLEASE |
| | SHOW THE NEW CEILING HEIGHT TO COMPLY WITH FBC 1208.2 |
| | MINIMUM CEILING HEIGHTS. |
| | OCCUPIABLE SPACES, HABITABLE SPACES AND CORRIDORS SHALL |
| | HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET 6 INCHES |
| | (2286 MM) ABOVE THE FINISHED FLOOR. BATHROOMS, TOILET |
| | ROOMS, KITCHENS, STORAGE ROOMS AND LAUNDRY ROOMS SHALL |
| | HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET (2134 MM) |
| | ABOVE THE FINISHED FLOOR. |
| | |
| | 5) PLEASE PROVIDE THE CIVIL PLAN FOR THE SITE DRAINAGE |
| | - PER NOTES ON DRAWING A.300 - FBC WPB 107.2.5 SITE |
| | PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED WITH THE |
| | APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY A SITE |
| | PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF NEW |
| | CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, |
| | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES |
| | AND THE PROPOSED FINISHED GRADES, DEPICTING THE |
| | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD |
| | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT |
| | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND |
| | INCLUDED ON A BOUNDARY LINE SURVEY. |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |