| 2021-11-15 14:38:14 | 1.SECTION 94-442(C)(2)A. SINGLE FAMILY DWELLING UNITS |
| | GROSS LOT SQUARE FOOTAGE MINUS |
| | BUILDING FOOTPRINT SQUARE FOOTAGE EQUALS |
| | OPEN SPACE SQUARE FOOTAGE (ALL NON-BUILDING AREA) |
| | ONE TREE REQUIRED FOR EACH 1,000 SQ. FT OF OPEN SPACE |
| | OR PORTION THEREOF |
| | ONE SHRUB REQUIRED FOR EACH 500 SQ. FT OF OPEN SPACE OR |
| | PORTION THEREOF. |
| | |
| | A. SHOW THE REQUIRED CALCULATION AND PROVIDED TREES AND |
| | SHRUBS BASED ON THE OPEN SPACE SQUARE FOOTAGE |
| | REQUIREMENTS. USE CALCULATION: LOT SIZE SQ. FT. |
| | SUBTRACTED BY HOME BUILDING FOOTPRINT EQUALS THE OPEN |
| | SPACE SQUARE FOOTAGE . POOLS, DRIVES SIDE WALKS SHOULD |
| | NOT BE COUNTED IN THE CALCULATION. |
| | |
| | 2.SECTION 94-442 (D) SUBSTITUTION OF PALM TREES. |
| | PALM TREES MAY BE SUBSTITUTED FOR NOT MORE THAN 35 |
| | PERCENT OF THE SHADE OR FLOWERING TREES REQUIRED BY |
| | THIS ARTICLE. HOWEVER, WHEN PALM TREES ARE SUBSTITUTED |
| | FOR SHADE TREES, THREE PALM TREES SHALL BE PROVIDED FOR |
| | EACH REQUIRED SHADE TREE. THIS 3:1 SUBSTITUTION SHALL |
| | NOT BE REQUIRED FOR ROYAL PALM TREES (ROYSTONEA SPP.), |
| | SENEGAL DATE PALM (PHOENIX RECLINATA), MEDJOOL DATE |
| | PALM (PHOENIX DACTYLIFERA), BISMARCK PALM (BISMARCKIA |
| | NOBILIS), AND SILVER DATE PALM (PHOENIX SYLVESTRIS). |
| | |
| | 3.SECTION 94-442 (G) FLORIDA FRIENDLY LANDSCAPE |
| | REQUIREMENTS |
| | LANDSCAPE PLAN MUST SATISFY A MINIMUM TOTAL OF 25 |
| | POINTS FROM THE DESIGN OPTIONS CHART. |
| | |
| | A. PROVIDE DESIGN CHART, OPTIONS TAKEN AND SHOW 25 |
| | TOTAL POINTS. MUST BE VISIBLE ON SUBMITTED DESIGN. |
| | |
| | B. CHART CAN BE FOUND AT WEB LINK . |
| | HTTP://ONLINE.ENCODEPLUS.COM/REGS/WESTPALMBEACH-FL/DOC- |
| | VIEWER.ASPX#SECID-701 |
| | |
| | |
| | 4.SECTION 94-445 (4) REQUIRED PLANT MATERIAL |
| | SPECIFICATIONS. |
| | SHADE AND FLOWERING TREES MINIMUM 12 FEET IN HEIGHT AND |
| | FLORIDA GRADE #1 OR BETTER QUALITY. |
| | PALM SPECIES MINIMUM EIGHT FEET CLEAR WOOD. |
| | SHRUBS MINIMUM OF 3GALLON, GROUNDCOVER MAY BE SMALLER. |
| | |
| | |
| | 5. SECTION 94-445 I. |
| | PLANT SPECIES. A MINIMUM OF 60 PERCENT OF PLANT |
| | MATERIAL ADDED SHALL BE FLORIDA NATIVE OR DROUGHT |
| | TOLERANT SPECIES SELECTED FROM THE CITY LIST OR THE |
| | LIST OF SPECIES IN THE MOST RECENT EDITION OF SOUTH |
| | FLORIDA WATER MANAGEMENT DISTRICT WATERWISE SOUTH |
| | FLORIDA LANDSCAPES. |
| | A. PROVIDE TOTAL PERCENTAGE BASED ON PLAN LIST. |
| | INFORMATION MUST BE VISIBLE ON SUBMITTED DESIGN. |
| | |
| | 6. PROVIDE ARTIFICIAL TURF DOCUMENTATION LISTING THE |
| | MINIMUM MATERIAL STANDARDS. |
| | |
| | 94-451 E .MINIMUM MATERIAL STANDARDS. ALL ARTIFICIAL |
| | TURF SHALL COMPLY WITH EACH OF THE FOLLOWING MINIMUM |
| | STANDARDS: |
| | ARTIFICIAL TURF SHALL CONSIST OF GREEN LIFELIKE |
| | INDIVIDUAL BLADES OF GRASS THAT EMULATE NATURAL TURF IN |
| | LOOK AND COLOR. |
| | WHERE ARTIFICIAL TURF IS UTILIZED FOR INSTITUTIONAL |
| | RECREATIONAL USES (E.G., PLAYGROUNDS, ATHLETIC FIELDS), |
| | THE ARTIFICIAL TURF PRODUCT INSTALLED SHALL BE DESIGNED |
| | FOR THE INTENDED USE AND MEET THE APPROPRIATE |
| | ADDITIONAL STANDARDS. |
| | ARTIFICIAL TURF INSTALLATIONS SHALL HAVE A MINIMUM |
| | PERMEABILITY OF 30 INCHES PER HOUR PER SQUARE YARD. |
| | ALL ARTIFICIAL TURF SHALL HAVE A MINIMUM EIGHT YEAR |
| | MANUFACTURER'S WARRANTY THAT PROTECTS AGAINST COLOR |
| | FADING AND A DECREASE IN PILE HEIGHT. |
| | ARTIFICIAL TURF SHALL BE LEAD FREE. |
| | ALL MATERIALS MUST INCLUDE TEST DOCUMENTATION WHICH |
| | DECLARES THAT THE ARTIFICIAL TURF YARN AND BACKING |
| | MATERIALS ARE DISPOSABLE UNDER NORMAL CONDITIONS, AT |
| | ANY U.S. LANDFILL STATION (TOTAL CONTENT LEACH PROTOCOL |
| | (TCLP) TEST). DOCUMENTATION MUST ALSO BE PROVIDED THAT |
| | IDENTIFIES ALL COMPONENTS THAT ARE RECYCLABLE AND ALL |
| | COMPONENTS THAT CONSIST OF RECYCLED MATERIAL. |
| | THE USE OF INDOOR OR OUTDOOR PLASTIC OR NYLON CARPETING |
| | AS A REPLACEMENT FOR ARTIFICIAL TURF OR NATURAL TURF |
| | SHALL BE PROHIBITED. |
| | |
| | 7. THE SATAKE PALMS DO NOT APPEAR TO BE IN COMPLIANCE |
| | OF FPL RIGHT TREE IN THE RIGHT PLACE. PLAMS NEED TO BE |
| | SET BACK APPROPERATE DISTANCE FROM FPL UTILITY LINES. |
| | |
| | 8. IF EXISTING TREES OR PLAMS ARE TO BE REMOVED OR |
| | RELOCATED A TREE ALTERATION PERMIT IS REQUIRED . |
| | |
| | ANDREW BURNETT |
| | 561-822-1562 |
| | |
| | |
| | |
| | |