| 2021-12-27 15:53:30 | RESTROOM BUILDING |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | |
| | 1) PLEASE PROVIDE A SITE PLAN SHOWING THE FOLLOWING |
| | INFORMATION FBC WPB 107.2.5 SITE PLAN. THE CONSTRUCTION |
| | DOCUMENTS SUBMITTED WITH THE APPLICATION FOR PERMIT |
| | SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE |
| | THE SIZE AND LOCATION OF NEW CONSTRUCTION AND EXISTING |
| | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE |
| | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED |
| | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS |
| | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN |
| | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE |
| | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE |
| | SURVEY. |
| | |
| | 2) PLEASE PROVIDE A SURVEY SHOWING EASEMENTS, FLOOD |
| | ZONE ETC. |
| | |
| | 3) PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, EXTERIOR |
| | DOORS AND LOUVERS NEED TO BE REVIEWED AND MARKED |
| | APPROVED BY THE BUILDING DESIGNER OF RECORD. FBC WPB |
| | 107.3.4 |
| | |
| | 4) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET GRAB |
| | BAR DIMENSIONS FROM THE FINISHED FLOOR TO THE "TOP OF |
| | THE GRIPPING SURFACE" PER FBC A 609.4 POSITION OF GRAB |
| | BARS. |
| | GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, |
| | 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM) |
| | MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF |
| | THE GRIPPING SURFACE, |
| | |
| | 5) ACCESSIBLE RESTROOM - PLEASE SHOW THE MIRROR |
| | DIMENSIONS FROM THE FINISHED FLOOR TO THE "REFLECTIVE |
| | SURFACE" PER FBC A 603.3 MIRRORS. |
| | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | 6) DRAWING A-1 - DETAIL A4 - SHOWS RH2 ABOVE THE GRAB |
| | BAR - FBC 609.3 THE SPACE BETWEEN THE GRAB BAR AND |
| | PROJECTING OBJECTS ABOVE SHALL BE 12 INCHES (305 MM) |
| | MINIMUM. |
| | |
| | 7) ATTIC ACCESS - FBC 1209.2 ATTIC SPACES. |
| | AN OPENING NOT LESS THAN 20 INCHES BY 30 INCHES (559 MM |
| | BY 762 MM) SHALL BE PROVIDED TO ANY ATTIC AREA HAVING A |
| | CLEAR HEIGHT OF OVER 30 INCHES (762 MM). CLEAR HEADROOM |
| | OF NOT LESS THAN 30 INCHES (762 MM) SHALL BE PROVIDED |
| | IN THE ATTIC SPACE AT OR ABOVE THE ACCESS OPENING. |
| | |
| | 8) SEPARATE PERMITS ARE REQUIRED FOR EACH BUILDING |
| | (RESTROOM EAST AND RESTROOM WEST). PLEASE SHOW THIS |
| | PERMIT TO BE FOR THE EAST OR THE WEST RESTROOM |
| | BUILDING. |
| | |
| | |