| Plan Review Notes For Permit 21101364 |
| Permit Number |
21101364 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-11-10 15:50:06 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21101364 | | | 11/10/21 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET A-1: THE PLAN SHOWS THE BREAK ROOM SINK | | | RELOCATED- PLEASE PROVIDE PLUMBING PLANS INCLUDING | | | RISER DIAGRAMS, AND FIXTURE SCHEDULE- SECTIONS 107.2.1 | | | & 107.3.5.1.3 WPB. THE PLANS SHALL INDICATE HOT WATER | | | IS BEING SUPPLIED TO THE SINK- SECTION 607.1 FBC P. | | | | | | 2) A-1: SHOW A CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS | | | FOR EITHER A FORWARD OR PARALLEL APPROACH TO THE SINK | | | PER SECTION 606.2 FBC ACC. IF A FORWARD APPROACH IS | | | CHOSEN PLEASE PROVIDE KNEE AND TOE CLEARANCES IN | | | ACCORDANCE WITH SECTIONS 606.2, 306.2, & 306.3 FBC ACC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|