| Date |
Text |
| 2022-07-22 16:31:01 | FAILED |
| | |
| | 1) UPDATED COMMENT: STAFF WILL ACCEPT YOUR WEIGHTED |
| | AVERAGE METHODOLOGY; HOWEVER, THE COMMENTS MUST BE |
| | ADDRESSED TO SATISFY STAFF THAT THE HOUSE DOES NOT |
| | EXCEED THE MAXIMUM HEIGHT ALLOWANCE. |
| | |
| | A. SHEET A-202 WAS NOT INCLUDED (SHEET A-201 WAS |
| | UPLOADED IN ITS PLACE), SO STAFF WAS UNABLE TO VERIFY |
| | THE UPDATED AVERAGE GRADE CALCULATION TABLE AND THE |
| | SHEET A-100 INFORMATION FOR THE EAST SIDE OF THE |
| | BUILDING. |
| | B. THANK YOU FOR PROVIDING ELEVATION TAGS ALONG THE |
| | SOUTH ELEVATION DRAWING TO MIRROR THE TAGS ON SHEET |
| | A-100. THE NORTH, EAST AND WEST ELEVATION DRAWINGS MUST |
| | ALSO INCLUDE THESE TAGS SO THAT STAFF CAN VERIFY THE |
| | MEASURE POINTS WITHOUT NEEDING TO SCALE THE PLAN. WHEN |
| | SCALING THE PLAN, THE WEST GRADE ELEVATION AT THE WEST |
| | GUEST 1 (LOWER) AND WEST LAUNDRY (HIGHER) DO NOT MATCH |
| | THE TABLE OR SHEET A-100. |
| | C. THE SOUTH ELEVATION DRAWING LISTS THE 1ST FLOOR SLAB |
| | AT 9.00 NAVD. HOWEVER, THE GRADE TAGS (ALSO SHOWN ON |
| | SHEET C-1) AND THE GRADE CROSS HATCH ARE SHOWN ABOVE |
| | THIS 9-FOOT MARK. THE GRADE THAT THE SLAB SITS ON |
| | CANNOT BE HIGHER THAN THE TOP OF THE SLAB (AS EVIDENCED |
| | BY SHEET S-411). ADDITIONALLY, THE AVERAGE FINISHED |
| | GRADE IS NOT MEASURED FROM THE TOP OF THE POOL DECK |
| | PAVERS, WHICH ARE THE VALUES USED BASED ON SHEET C-1). |
| | THE BUILDING HEIGHT IS MEASURED FROM THE AVERAGE |
| | FINISHED GRADE. |
| | D. PLEASE EXPLAIN WHY THE NORTH ENTRY (37.83 LINEAR |
| | FEET AT 6.29 FEET ELEVATION) DOES NOT INCLUDE THE LOWER |
| | HEIGHTS SHOWN ADJACENT TO THE NORTH ENTRY WALL ON THE |
| | WEST LIB POWDER AND EAST ? GUEST BATH (5.97 FEET |
| | ELEVATION) FOR APPROXIMATELY 19 OF THE 38 FEET. THIS |
| | WILL BRING THE 6.29-FOOT MEASURE DOWN. |
| | |
| | 2) UPDATED COMMENT: THERE ARE TWO SEPARATE KITCHEN |
| | AREAS SHOWN, WHICH IS NOT PERMITTED IN A SINGLE-FAMILY |
| | HOUSE. **** ALL SHEETS NEED TO BE UPDATED TO REFLECT |
| | THE REMOVAL OF THE OVEN IN THE BUTLER PANTRY, INCLUDING |
| | THE PIPING PLANS, THE POWER PLANS, THE ELECTRIC |
| | SCHEDULES, AND THE MECHANICAL PLANS. -- ZONING WILL NOT |
| | PASS THIS PERMIT UNTIL ALL PLANS REMOVE THE 2ND OVEN OR |
| | INCLUDE THE NOTE THAT THERE WILL BE NO OVEN IN THE |
| | BUTLER KITCHEN. HOWEVER, THE ELECTRIC SCHEDULE AND THE |
| | POWER PLAN MUST BE REVISED SHOW THE REMOVAL OF THE OVEN |
| | CIRCUIT, 240 OUTLET AND OVEN. |
| | |
| | 3) THE NEWLY SUBMITTED SHEET L1.0 SITE PLAN DOES NOT |
| | MATCH THE APPROVED LANDSCAPE PERMIT PLAN, NOR DOES IT |
| | MATCH THE LAYOUT SHOW ON SHEETS A-100 ARCHITECTURAL |
| | SITE PLAN, C-1 SITE PLAN THE ELEVATION PLANS, AND S-101 |
| | FOUNDATION PLAN. ALL PLANS MUST SHOW THE SAME, |
| | ACCURATE, CODE COMPLIANT CONDITIONS. NOTE: SHEET C-1 |
| | WAS NOT UPDATED TO REFLECT LATEST CHANGES, SO STAFF IS |
| | UNABLE TO VERIFY CODE COMPLIANCE. |
| | |
| | 4) THE NEW SHEET L1.0 SHOWS A BBQ AREA AND OUTDOOR |
| | SHOWER ON SCREENING WALL AND EXTENDED DECK WITHIN THE |
| | REQUIRED FIVE-FOOT SIDE SETBACK. PROVIDE DETAILS ON |
| | EACH OF THESE ITEMS. |
| | |
| | A. IF THE PAVED DECK IS LESS THAN 18 INCHES ABOVE |
| | GRADE, IT MAY NOT BE LOCATED CLOSER THAN TWO FEET FROM |
| | THE PROPERTY LINE. THIS WAS A COMMENT MADE UPON THE |
| | FIRST PLAN REVIEW FOR THIS LOCATION, WAS CORRECTED AND |
| | NOW APPLIES AGAIN. |
| | B. A FIXED BBQ GRILL IS AN ACCESSORY STRUCTURE AND MUST |
| | CONFORM TO THE REQUIRED MINIMUM SETBACKS. |
| | C. THE SHOWER SCREEN WALL MAY NOT EXCEED SIX FEET ABOVE |
| | THE GRADE OF THE PROPERTY TO THE SOUTH. THE SURVEY AND |
| | SHEET C-1 INDICATE THAT THE EXISTING GRADE AT THE |
| | PROPERTY LINE IN THIS LOCATION IS 3.4 FEET, WITH THE |
| | PROPOSED DECK ELEVATION AT JUST UNDER NINE FEET. THIS |
| | PROHIBITS ANY ADDITIONAL WALL HEIGHT AT THIS LOCATION. |
| | D. NONE OF THE PIPING PLANS INCLUDE THIS NEW LAYOUT. |
| | |
| | 5) PLEASE DESCRIBE WHAT THE STORAGE RACK THAT IS NOW |
| | SHOWN ON THE SOUTH SIDE OF THE BUILDING WILL BE USED |
| | FOR AND PROVIDE AN ELEVATION DRAWING. |
| | |
| | 6) SEPARATE PERMITS ARE REQUIRED FOR THE ITEMS LISTED |
| | BELOW. PLEASE NOTE THAT STAFF HAS NOT FULLY REVIEWED |
| | ANY OF THE ITEMS AS PART OF THIS PERMIT APPLICATION TO |
| | VERIFY THAT THE INFORMATION SHOWN COMPLIES WITH CODE |
| | BUT HAS NOTED SOME ITEMS AS LISTED. THIS PERMIT REVIEW |
| | IS ONLY FOR THE HOUSE. |
| | |
| | A. IRRIGATION |
| | B. POOL - THE POOL CONFIGURATION HAS BEEN CHANGED. FULL |
| | COMPLIANCE REVIEW WILL BE WITH THE REQUIRED POOL |
| | PERMIT. |
| | C. GENERATOR |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |
| | |
| | |
| | |