| Date |
Text |
| 2022-03-22 16:37:03 | FAILED |
| | |
| | 1) UPDATED COMMENT: PROVIDE THE HEIGHT DIMENSIONS IN |
| | ACCORDANCE WITH THE CITY'S ZONING AND LAND DEVELOPMENT |
| | CODE REGULATIONS - THE HEIGHT SHALL BE MEASURED AS THE |
| | VERTICAL DISTANCE FROM THE AVERAGE ELEVATION OF THE |
| | FINISHED GRADE OF THE BUILDING TO THE HIGHEST POINT OF |
| | THE TOP OF THE STRUCTURE OF A FLAT ROOF, OR TO THE DECK |
| | LINE OF A MANSARD ROOF, OR TO THE MEAN HEIGHT LEVEL |
| | BETWEEN EAVES AND RIDGE FOR GABLE, HIP, AND GAMBREL |
| | ROOFS. THE MEASURE POINT NEEDS TO START AT THE AVERAGE |
| | FINISHED GRADE, NOT THE TOP OF THE FLOOR SLAB AND |
| | INCLUDE THE HIGHEST RIDGE AND THE EAVE DIMENSIONS. **** |
| | PLEASE PROVIDE HOW YOU DETERMINED THE AVERAGE ELEVATION |
| | OF SIX INCHES BELOW THE SLAB WHEN THERE IS A |
| | SIGNIFICANT PERCENTAGE OF THE GRADE FOR THE WESTERN |
| | PORTION OF THE HOUSE IS 2-3 FEET BELOW THE SLAB. |
| | |
| | 2) REPEAT COMMENT: THERE ARE TWO SEPARATE KITCHEN AREAS |
| | SHOWN, WHICH IS NOT PERMITTED IN A SINGLE-FAMILY HOUSE. |
| | **** ALL SHEETS NEED TO BE UPDATED TO REFLECT THE |
| | REMOVAL OF THE OVEN IN THE BUTLER PANTRY, INCLUDING THE |
| | PIPING PLANS, THE POWER PLANS, THE ELECTRIC SCHEDULES, |
| | THE MECHANICAL PLANS, THE REFLECTED CEILING PLAN, AND |
| | THE FIRST FLOOR DIMENSION PLAN. |
| | |
| | 3) UPDATED COMMENT: THE PLANS SHOW ARTIFICIAL TURF, |
| | WHICH IS ONLY LOCATED WITHIN THE SIDE OR REAR SETBACK, |
| | WHICH IS NOT WHERE YOU HAVE SHOWN IT. **** THE RESPONSE |
| | STATES THAT THE LANDSCAPE PLANS DO NOT SHOW ARTIFICIAL |
| | TURF; HOWEVER, THERE IS A NOTE ON SHEET L1 THAT STATES, |
| | "STRIP DRAIN UNDER ART TURF" AND SHEET C1 HAS AN AREA |
| | LABELED AS "ARTIFICIAL TURF". |
| | |
| | 4) SEPARATE PERMITS ARE REQUIRED FOR THE ITEMS LISTED |
| | BELOW. PLEASE NOTE THAT STAFF HAS NOT FULLY REVIEWED |
| | ANY OF THE ITEMS AS PART OF THIS PERMIT APPLICATION TO |
| | VERIFY THAT THE INFORMATION SHOWN COMPLIES WITH CODE |
| | BUT HAS NOTED SOME ITEMS AS LISTED. THIS PERMIT REVIEW |
| | IS ONLY FOR THE HOUSE. |
| | |
| | A. DRIVEWAY AND APPROACH. |
| | B. IRRIGATION |
| | C. POOL - BY THE ZONING AND LAND DEVELOPMENT CODE |
| | DEFINITION, THE PROPOSED POOL IS AN ABOVE GROUND |
| | SWIMMING POOL. ABOVE GROUND SWIMMING POOLS ARE |
| | PROHIBITED IN THE CITY OF WEST PALM BEACH. |
| | ADDITIONALLY, A PORTION OF THE INFINITY EDGE CAPTURE |
| | AREA IS WITHIN THE 25-FOOT FRONT SETBACK, WHICH IS NOT |
| | PERMITTED. |
| | D. GENERATOR |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |
| | |