| 2021-12-20 11:13:52 | RESIDENTIAL (R3) ROOFING REVISION BUILDING REVIEW | | | COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | REVISION #21101177 | | | | | | | | | NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK | | | SHALL COMPLY WITH THE MATERIALS AND METHODS | | | REQUIREMENTS IN THE FLORIDA BUILDING CODE. | | | | | | 1- FLAT ROOF NOA 20-0131.01 SUBMITTED: CLEARLY MARK | | | WHICH APPROVED ASSEMBLY IS GOING TO BE INSTALLED TO | | | VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC. | | | R301.2.1 FBC-RESIDENTIAL. NOTE: IF THE SELECTED | | | ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES FOR ALL ROOF | | | ZONES, THEN SIGNED AND SEALED RAS 117 CALCULATIONS ARE | | | REQUIRED. SEE GENERAL LIMITATION #7 ON LAST PAGE OF | | | NOA. ASSEMBLIES WITH GENERAL LIMITATION #9 CAN NOT BE | | | USED IF THEY DON'T MEET THE DESIGN PRESSURES FOR ALL | | | ROOF ZONES. | | | | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|