Plan Review Notes
Plan Review Notes For Permit 21101102
Permit Number 21101102
Review Stop M
Sequence Number 1
Notes
Date Text
2021-10-28 10:40:571) THE PERMIT APPLICATION IS FOR AC CHANGE OUT OF 3
 LENNOX SYSTEMS W/ DUCTWORK REPLACEMENT BUT THE DRAWING
 PROVIDED SHOWS ONLY 1 SYSTEM. PLEASE PROVIDE DRAWINGS
 FOR EACH SYSTEM AS INDICATED ON THE PERMIT APPLICATION.
  
 2) PLEASE PROVIDE DRAWINGS OF THE COMPLETE SYSTEMS
 INCLUDING THE DUCT SIZES OF EACH DUCT, THE CONDENSATE
 PIPING, SIZE AND TERMINATION LOCATION ALONG WITH THE
 CONDENSING UNITS LOCATION AND TIE DOWN METHOD. FBC
 107.2.1
  
 3) THE DESIGNER OF THE DRAWINGS MUST INCLUDE A
 TITLEBLOCK WHICH HAS THEIR PRINTED NAME AND SIGNATURE.
  
  