| 2022-03-24 12:10:42 | 1. NOT SATISFIED. REVISED C-13 SHEET SHOW AN ADA RAMP |
| | GOING DOWN FROM SIDEWALK TO DRIVEWAY LEVEL. THE |
| | SIDEWALK LEVEL SHALL BE MAINTANED ACROSS DRIVEWAY, THAT |
| | MEANS THE APRON NEEDS TO REACH THE SIDEWALK LEVEL BY |
| | THE TIME IS MEETS THE SIDEWALK. PREVIOUS |
| | COMMENT:SIDEWALK ELEVATION SHALL BE MAINTAINED ACROSSED |
| | GARAGE DRIVEWAYS ON 8TH AND EUCALYPTUS. PLEASE INCLUDE |
| | DETAILS IN CIVIL DRAWINGS TO ENSURE COMPLIANCE. |
| | 2. SATISFIED. A PORTION OF THE PUBLIC OPEN SPACE NEEDS |
| | TO BE INDICATED AS PRIVATE TO COMPLY WITH 25% REQUIRED. |
| | THE SPACE COULD REMAIN AS PART OF THE PUBLIC OPEN SPACE |
| | DESIGN, IT JUST NEEDS TO BE SHOWN IN THE CLASSIFICATION |
| | OF THE PRIVATE TO CONFIRM COMPLIANCE (SHEET A-03) |
| | 3. SATISFIED. ALL CALCULATIONS AND INFORMATION ABOUT |
| | COMPLIANCE WITH THE OPEN SPACE REQUIREMENTS SHALL BE |
| | INCLUDED IN THE LANDSCAPE SUBMITTAL. |
| | 4. SATISFIED. PLEASE PROVIDE PHOTOMETRICS TO CONFIRM |
| | THE 0.6 FOOTCANDLE MINIMUM REQUIRED AT THE CURB ONE |
| | FOOT ABOVE GRADE IS MET. |
| | 5. SATISFIED. PLEASE ENSURE THE SFX SLIPFITTER IS BEING |
| | USED.- PREVIOUS COMMENT:PROPOSE STREET LIGHT FIXTURE |
| | DOES NOT MATCH DOWNTOWN STANDARD. LIGHT FIXTURE TO BE |
| | INSTALLED ALONG THE STREET SHALL MATCH THE DOWNTOWN |
| | STANDARD. PLEASE ADJUST. |
| | 6. SATISFIED - PARKING SPACES FOR GUEST AND RETAIL |
| | SHALL BE INDICATED ON DRAWINGS AND SIGNS SHALL BE |
| | PROVIDED IN GARAGE. HOW DO GUESTS AND RETAIL CLIENTS |
| | GET ACCESS THROUGH THE GATE? |
| | 7. SATISFIED.- PLEASE PROVIDE A COMPLETE ELEVATION OF |
| | THE BRIDGE. |
| | 8. SATISFIED - PLEASE PROVIDE INFORMATION ON THE FDOT |
| | APPROVAL OF THE PROPOSED CHANGES ALONG DIXIE HIGHWAY. |
| | 9. SATISFIED - COMMENT FOR SOUTH BUILDING - PREVIOUS |
| | COMMENT:PLEASE PROVIDE INFORMATION ABOUT THE SEATING |
| | WITHN THE PUBLIC OPEN SPACE AND ANY PRIVATE OPEN SPACE |
| | LOCATED ALONG THE STREET. |
| | 10. SATISFIED - PLEASE CONFIRM THAT THE SCORE LINE |
| | PATTERN INCLUDED IN THE SITE PLAN APPROVAL IS |
| | MAINTAINED. |
| | 11. NOT SATISFIED . FPL TRANSFORMERS ARE ENCROACHING |
| | MORE THAN 4 FEET INTO THE MINIMUM 15 FEET SIDE SETBACK. |
| | EQUIPMENT NEEDS TO BE MOVED TOWARDS THE WEST. - |
| | PREVIOUS COMMENT: PLEASE PROVIDE AN EXHIBIT INDICATING |
| | THE LOCATION OF ALL ABOVE GROUND UTILITY CONNECTIONS |
| | LOCATED ALONG THE FRONTAGE LINE. NO ABOVE GROUND |
| | UTILITIES CAN BE LOCATED WITHIN THE MINIMUM SETBACK. |
| | 12.SATISFIED - A SEPARATE PERMIT SHALL BE SUBMITTED FOR |
| | LANDSCAPE, IRRIGATION AND STREET LIGHTS. |
| | 13.SATISFIED - PLEASE PROVIDE INFORMATION ABOUT THE |
| | PROPOSED LIGHTING INSIDE THE GARAGE TO CONFIRM THE |
| | SOURCE IS HIDDEN FROM EXTERIOR VIEW. |