Plan Review Notes
Plan Review Notes For Permit 21100740
Permit Number 21100740
Review Stop B
Sequence Number 2
Notes
Date Text
2022-01-14 09:45:30BUILDING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 2ND REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 1. PROVIDE HANDRAILS PER R311.7.8
 R311.7.8 HANDRAILS.
 HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF
 EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR
 MORE RISERS. R311.7.8.
 HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED
 PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF
 RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM)
 AND NOT MORE THAN 38 INCHES (965 MM). R311.7.8.1 HEIGHT
  
 (GUARDS MAY BE USED AS HANDRAILS WITH EXCEPTION) SEE
 BELOW
 (REF. PLAN PAGE S.2. THE TOP OF THE GUARD AT THE 1ST
 FLIGHT OF STAIRS IS AT 42". R312.1.2HEIGHT. EXCEPTIONS:
 2. WHERE THE TOP OF THE GUARD SERVES AS A HANDRAIL ON
 THE OPEN SIDES OF STAIRS, THE TOP OF THE GUARD SHALL BE
 NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38
 INCHES (965 MM) AS MEASURED VERTICALLY FROM A LINE
 CONNECTING THE LEADING EDGES OF THE TREADS).
  
  
 2. CORRECTED
  
 3. RENAME FILES S2 AND S3 FROM WOOD STAIRS TO CONCRETE
 STAIRS. (NOT ADDRESSED)
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RE-SUBMITTING, PLEASE UPLOAD YOUR DOCUMENTS TO
 PROJECT DOX.
 DO NOT E-MAIL DOCUMENTS TO THE PLANS EXAMINER.
  
  