2022-02-11 11:43:01PREVIOUS ZONING REVIEW COMMENTS/RESPONSES 12/16/21:
  
 1. PLEASE PROVIDE DIMENSION OR DETAIL SHOWING THAT THE
 AC UNIT IS 12 IN. FROM PROPERTY LINE, MAXIMUM
 ENCROACHMENT IS 4 FT. INTO ANY SETBACK.
  
 [SATISFIED] AC UNIT SHALL BE SCREENED WITH LANDSCAPE
 HEDGES.
  
 2. PLEASE IDENTIFY LOCATION AND TYPE OF PRIVATE OPEN
 SPACE, HOW IS THE 12% REQUIREMENT BEING MET. DESIGNED
 OPEN SPACE THAT IS ACCESSIBLE, PLEASE REFERENCE
 STANDARDS IN SEC. 94-109 TABLE IV-7 FOR TYPES OF
 PRIVATE OPEN SPACE AND STANDARDS, MAY WANT TO CONSIDER
 TERRACE OR GARDEN OPTIONS.
  
 [NOT SATISFIED] THE PRIVATE OPEN SPACE WITHIN THE
 ENTRANCE AREAS DOES NOT SATISFY THE OPEN SPACE
 REQUIREMENT/DOES NOT COUNT TOWARD TOTAL. PLEASE
 DELINEATE ON THE PLANS THE APPROPRIATE LOCATION AND
 SQUARE FOOTAGE TOTAL REQUIRED TO MEET THE SPACE
 STANDARD (12% OR 847 SF).
  
 PROVISO: EXACT PRIVATE OPEN SPACE TYPE AND LANDSCAPE
 REQUIREMENTS (% TREE CANOPY AND % VEGETATED AREA) SHALL
 BE INCLUDED WITH THE PROPERTY?S PHASE II PERMIT. IF THE
 PHASE I CONSTRUCTION IS COMPLETED PRIOR TO THE
 COMMENCEMENT OF PHASE II?S PERMITTING AND CONSTRUCTION,
 THEN THE REQUIRED PRIVATE OPEN SPACE REQUIREMENTS SHALL
 BE COMPLETED/MET BEFORE ISSUANCE OF THE PHASE I CO.
  
 3. WHERE DOES THE GARBAGE/SANITATION GO? NEED SPACE FOR
 STORING CANS/DUMPSTER AND WILL THESE BE ROLLED OUT TO
 THE STREET?
  
 [PARTIALLY SATISFIED] PROPOSED DUMPSTER ENCLOSURE SHALL
 BE ROTATED AND SHIFTED TO FACE AND OPEN TOWARD THE
 NORTHERN PROPERTY-LINE, NOT THE PARK OR FRONTING 7TH
 STREET. ENCLOSURE SHALL BE SCREENED WITH LANDSCAPING
 HEDGES. SUGGEST INCLUSION OF CONCRETE PAD TO ROLL THE
 DUMPSTER OUT TO CURB/ROADWAY FOR PICKUP.
  
 4. TREE GRATES CAN BE 4FT. X 4FT., PLEASE PUSH THEM
 CLOSER TO THE CURB TO ALLOW A WIDER CLEAR PATH ON THE
 SIDEWALK. MAKE SURE GRATE IS ADA COMPLIANT AND MEETS
 THE CITY STANDARD. PUSH THE EXISTING GRATE CLOSER TO
 CURB TO MATCH NEW ONES.
  
 [SATISFIED]
  
 5. REQUIRED NUMBER OF STREET TREES IS 5, ALONG THE N.
 ROSEMARY FRONTAGE. ONLY 4 SHOWN.
  
 [SATISFIED]
  
 6. SIGNAGE ABOVE CANOPY CANNOT PROJECT MORE THAN 18?
 FROM FACE OF BUILDING. MOUNT DIRECTLY TO BUILDING
 FACADE.
  
 [SATISFIED] SIGNAGE TO BE INCLUDED IN SEPARATE PERMIT.
  
 7. PLEASE INCLUDE A PHOTOMETRIC PLAN. SITE LIGHTING
 MUST MEET 0.6 FOOT CANDLES. THIS VALUE CAN BE MET WITH
 LIGHTS MOUNTED ON THE BUILDING.
  
 [NOT SATISFIED] PROVIDE PROOF THAT PHOTOMETRICS ARE MET
 ONSITE WITH EXISTING STREET LIGHTS OR ADDITIONAL
 WALL/BUILDING MOUNTED FIXTURES
  
 8. INCLUDE A SINGLE BIKE RACK WITHIN THE PUBLIC ROW.
  
 [SATISFIED]
  
 9. PLEASE IDENTIFY LOCATION OF NEW/EXISTING CONCRETE
 ELECTICAL OR FPL POLES.
  
 [SATISFIED]
  
 10. PLEASE INCLUDE A LANDSCAPE PLAN FOR THE SITE.
  
 [SATISFIED] LANDSCAPE PLANS SHALL BE SUBMITTED UNDER
 SEPARATE PERMIT.
  
  
  
 NEW ZONING REVIEW COMMENT 2/11/22:
  
 1. PLEASE WIDEN OR PROVIDE ADDITIONAL 2FT. OF SPACE
 ALONG THE SIDEWALK AREA (CUT EXISTING CONCRETE SLAB) TO
 PROVIDE A 6FT. CLEAR PATH SECTION OF SIDEWALK BETWEEN
 THE TREE GRATES AND INTERIOR SITE ALONG THE N ROSEMARY
 STREET FRONTAGE.
  
  
 CHRIS KIMMERLY, URBAN DESIGN PLANNER
 822-1426
  
  