| Plan Review Notes For Permit 21100604 |
| Permit Number |
21100604 |
|
| Review Stop |
E |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-11-03 14:17:50 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY BN, BU, PX | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) FBC R314 SMOKE ALARM IS REQUIRED PER FBC. | | | | | | PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED PER | | | CODE. SHOW ON PLAN ALL EXISTING ALARMS. IF NONE ARE | | | EXISTING OR NOT TO CODE, SHOW AS NEW INSTALLATIONS. FBC | | | R314.3, FBC 107.2.1 | | | | | | 2) LIGHTING OUTLET IS REQUIRED BY 210.70 OF THE NEC | | | | | | 210.70(A)(1) HABITABLE ROOMS. AT LEAST ONE WALL | | | SWITCH?CONTROLLED | | | LIGHTING OUTLET SHALL BE INSTALLED IN EVERY HABITABLE | | | ROOM, | | | KITCHEN, AND BATHROOM. |
|