2022-10-26 18:19:50RESIDENTIAL (R3) ADDITION, ALTERATION 4TH BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21100379
 102 GREGORY RD
  
 PREVIOUS COMMENT:
 1- REPEAT COMMENT. THREE TIMES. NOT ADDRESSED AT ALL.
 NEED TO SUBMIT CONSTRUCTION DRAWINGS ELEVATION
 CERTIFICATE AND SURVEY FOR REVIEW.
  
 RESPONSE:
 A) SURVEY SUBMITTED IS FOR THE OLD HOUSE AND GARAGE.
 NEED SURVEY WITH PROPOSED CONSTRUCTION IN ORDER TO
 REVIEW ELEVATION CERTIFICATE SUBMITTED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 B)ELEVATION CERTIFICATE SUBMITTED:
 (1) BUILDING OWNER'S NAME IS INCORRECT. REVISE AS
 REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (2)PROPERTY LEGAL DESCRIPTION DOESN'T MATCH INFORMATION
 SHOWN ON THE SURVEY SUBMITTED. REVISE AS REQUIRED TO
 MATCH.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (3)BUILDING DIAGRAM NUMBER ON ITEM A7 IS INCORRECT.
 REVISE AS REQUIRED. SEE FEMA ELEVATION CERTIFICATE
 INSTRUCTIONS AND REVISE AS REQUIRED. IT LOOKS LIKE THIS
 IS DIAGRAM NUMBER 1B NOT 7.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (4)THE TOTAL NET AREA OF FLOOD OPENING IN ITEM A9(C) IS
 INCORRECT. SEE PLANS AND FLOOD VENT PRODUCT APPROVAL
 AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (5)THE BASE FLOOD ELEVATION SPECIFIED ON ITEM B9 IS
 INCORRECT. SEE FLOOD INSURANCE RATE MAP (FIRM) AND
 REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (6)TOP OF BOTTOM FLOOR ELEVATION SPECIFIED ON ITEM
 C2(A) IS INCORRECT. SEE PLANS AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (7)ATTACHED GARAGE ELEVATION SPECIFIED ON ITEM C2(D) IS
 INCORRECT. SEE PLANS AND REVISE AS REQUIRED.
 SEC.107.2.1 CITY AMENDMENTS.
  
 (8)LOWEST ELEVATION OF AIR CONDITIONING UNIT SPECIFIED
 ON ITEM C2(E) DOESN'T COMPLY WITH CITY ORDINANCE
 4729-17.ELEVATION OF EQUIPMENT NEEDS TO BE 2 FEET ABOVE
 THE BASE FLOOD ELEVATION (9'-0" MIN.). COORDINATE WITH
 ENGINEER OF RECORD AND REVISE AS REQUIRED.
  
 (9) LOWEST ADJACENT (FINISHED) GRADE AND HIGHEST
 ADJACENT (FINISHED) GRADE WILL BE REVIEWED ONCE REVISED
 SURVEY WITH PROPOSED CONSTRUCTION IS SUBMITTED.
  
  
 PREVIOUS COMMENT:
 2- DRAINAGE PLAN SUBMITTED IS FOR THE EXISTING
 STRUCTURES. NEED TO PROVIDE DRAINAGE PLAN WITH PROPOSED
 STRUCTURES.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 PREVIOUS COMMENT:
 15- PRODUCT APPROVALS
 PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001
 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. CONTRACTOR TO ADVISE IF SUBMITTING NOW OR
 LATER AS A DEFERRED SUBMITTAL).
  
  A)INSWING ENTRY DOORS A SHOWN ON PLANS.
  B)INSWING SIDE DOOR #4 AS SHOWN ON PLANS.
  C)SLIDING GLASS DOORS (NOTE: NEED FOR LARGE MISSILE
 IMPACT)
  D)OVERHEAD GARAGE DOOR.
  E)CASEMENT WINDOWS.
  F)SINGLE HUNG WINDOWS.
  G)FIXED WINDOWS.
  H)HORIZONTAL ROLLER
  WINDOWS.
  I)WINDOW MULLIONS (NOTE: NEED TO SPECIFY
  MULLION SIZE TO AVOID DELAYS/CONFLICTS).
  J)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT
  GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE.
  K)SHINGLES.
  L)PEEL & STICK SHINGLES UNDERLAYMENT SPECIFIED ON
 PLANS.
  M)RIDGE VENTS AS SPECIFIED ON PLANS.
  N)FLOOD VENTS AS SPECIFIED ON PLANS.
  
 RESPONSE:
 ACCORDING TO ENGINEER OF RECORD RESPONSE LETTER ALL
 PRODUCT APPROVALS WILL BE APPROVED AND WILL BE
 SUBMITTED LATER AS DEFERRED SUBMITTALS.
 ONLY SOME PRODUCT APPROVALS WERE SUBMITTED AT THIS TIME
 AND THEY WERE NOT REVIEWED/APPROVED BY THE DESIGNER OF
 RECORD. ALSO, THE FLOOD VENT PRODUCT APPROVAL SUBMITTED
 IS INCOMPLETE. IT NEEDS THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND INSTALLATION INSTRUCTIONS. TO SAVE TIME,
 ALL PRODUCT APPROVALS SUBMITTED THIS TIME WILL BE
 BLOCKED AND WILL NOT BE REVIEWED AT THIS TIME.
 CONTRACTOR TO ADVISE IF SUBMITTING ALL THE PRODUCT
 APPROVALS (COMPLETE REPORTS) LATER AS A DEFERRED
 SUBMITTAL ONCE THEY ARE APPROVED BY THE DESIGNER OF
 RECORD OR IF SUBMITTING THEM ON NEXT RESUBMITTAL.
  
 NEW COMMENT BASED ON REVISED PLANS:
 16- SHEET A-2: ENGINEER REVISED THE BASE FLOOD
 ELEVATION UNDER FLOOD ZONE. THE REVISED INFORMATION IS
 INCORRECT. ACCORDING TO FLOOD INSURANCE RATE MAP (FIRM)
 DATED 10-05-2017 THE BASE FLOOD ELEVATION IS 7'-0" NOT
 6'-0". REVISE AS REQUIRED.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,