Plan Review Notes
Plan Review Notes For Permit 21100162
Permit Number 21100162
Review Stop Z
Sequence Number 1
Notes
Date Text
2021-11-29 14:10:11FAILED
  
 1) PROVIDE A SURVEY, PREPARED BY A FLORIDA LICENSED
 SURVEYOR, WHICH SHOWS THE POLE LOCATION AND THE
 RIGHT-OF-WAY LINE SO THAT STAFF CAN VERIFY THAT THE
 WIRELESS COMMUNICATION FACILITY IS WITHIN THE
 RIGHT-OF-WAY AND NOT ON PRIVATE PROPERTY. THE SURVEY
 MUST SHOW THE SETBACKS OF THE PROPOSED POST TO THE EDGE
 OF THE RIGHT-OF-WAY AND THE EDGE OF THE SIDEWALK, AS
 WELL AS THE SIDEWALK WIDTH.
  
 2) THE SURVEY MUST INCLUDE THE HEIGHTS OF UTILITY POLES
 (INCLUDING LIGHT POLES) ALONG DATURA STREET, SO THAT
 STAFF CAN VERIFY THAT THE PROPOSED 25 FOOT TALL POLE
 COMPLIES WITH THE POLE HEIGHTS LOCATED ALONG DATURA
 STREET. NOTE: THERE IS A COBRA HEAD LIGHT POLE EAST OF
 THE SITE THAT WILL MOST LIKELY SET YOUR MAXIMUM POLE
 HEIGHT.
  
 3) THE POLE COLOR WILL NEED TO MATCH THAT DECORATIVE
 STREET LIGHTS ON THE NORTH SIDE OF DATURA STREET (IT IS
 A SPECKLED GREY).
  
 4) THE PROPOSED POLE COMPLIES WITH CITY CONCEALMENT
 REQUIREMENTS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]