2022-01-18 13:55:42NEW SINGLE FAMILY RESIDENCE (R3)SECOND REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21100101
  
 ORIGINAL COMMENT:
 1-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 R101.5 FBC-ENERGY CONSERVATION.
 NOTE: PLEASE MAKE SURE FORM IS PROPERLY SIGNED BY ALL
 REQUIRED PARTIES AND IS COORDINATED WITH PLANS TO AVOID
 CONFLICTS/DELAYS.
  
 RESPONSE:
 A)ENERGY CALCULATIONS FORM IS REQUIRED TO BE CERTIFIED
 AT THE BOTTOM OF THE FORM BY THE OWNER, THE OWNER'S
 ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY
 THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY
 SEC. R103.1.1.2 FBC-ENERGY CONSERVATION.
  
 B)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE
 LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 ORIGINAL COMMENT:
 2- LOT DRAINAGE:
 PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING: R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY
 AMENDMENTS.
 SEC. 110.9 CITY AMENDMENTS.
 NOTE: PROPOSED HOUSE FOOTPRINT IS BIGGER THAN EXISTING
 HOUSE. ALSO, PLANS CALL FOR FUTURE POOL EQUIPMENT.
 NEIGHBORS ON THE EAST AND SOUTH SIDES ARE GOING TO BE
 AFFECTED. SITE/DRAINAGE PLAN SUBMITTED DOESN'T SHOW ANY
 GRADE ELEVATIONS. ALSO, DRAINAGE PLAN SUBMITTED DOESN'T
 SHOW HOW TO KEEP THE SURFACE WATER AWAY FROM ADJACENT
 NEIGHBORS. PROVIDE COMPLETE DRAINAGE PLAN WITH GRADE
 ELEVATIONS.
  
 RESPONSE:
 *FINISHED FLOOR ELEVATION SHOWN ON THE HOUSE IS LOWER
 THAN THE EXTERIOR GRADE ELEVATION. REVISE/CLARIFY AS
 REQUIRED. SEC. 107.2.1 CITY AMENDMENTS.
 **NOTE: BASED ON ZONING COMMENTS, BUILDING SETBACK ON
 THE EAST SIDE NEEDS TO BE 10'-0". DRAINAGE AND ALL
 PLANS NEED TO BE REVISED ACCORDINGLY. SEC. 107.2.1 CITY
 AMENDMENTS.
 ***PROVIDE DETAIL FOR DRAINAGE RETAINING LOW WALL ON
 EAST AND SOUTH SIDE OF PROPERTY. NOTE: SEPARATE FENCE
 PERMIT APPLICATION WILL BE REQUIRED FOR THIS LOW WALL.
  
 3- SHEET SP-1:
 A)OK.
  
 ORIGINAL COMMENT:
 B)SPECIFY ROOF TRUSSES DEAD AND LIVE LOADS. CLEARLY
 SPECIFY TOP AND BOTTOM LOADS. INCLUDING THE ATTIC LIVE
 LOAD AS REQUIRED BY TABLE R301.5 FBC-RESIDENTIAL.
 SEE FOOTNOTES "B" AND "G".
  
 RESPONSE:
 CLEARLY SPECIFY TRUSS TOP AND BOTTOM CHORD LIVE AND
 DEAD LOADS. WHAT IS THE DEAD LOAD FOR THE ROOF TILE?
 AND WHAT IS THE BOTTOM CHORD DEAD LOAD.? . SEC. R301.1
 FBC-RESIDENTIAL.
  
 4-11 OK.
  
 12- DEFERRED SUBMITTAL: PROVIDE PRODUCT APPROVAL AS
 REQUIRED BY FAC 61G20-3.001 FOR: ENTRY DOOR WITH
 TRANSOM ABOVE AS SHOWN ON PLANS, ALL WINDOW TYPES SHOWN
 ON PLANS, ALL DOORS SHOWN ON PLANS, WINDOW MULLIONS
 (AND SPECIFY SIZE), ROOF TILE, ROOF TILE ADHESIVE IF
 USED (SPECIFY SIZE), SHUTTERS IS DOORS/WINDOWS DON'T
 HAVE IMPACT GLASS(AND COMPLETE INSTALLATION SCHEDULE),
 DECORATIVE SHUTTERS SHOWN ON PLANS (AND COMPLETE
 INSTALLATION SCHEDULE),BALCONY UNDERLAYMENT FOR FINISH
 TILE AS SPECIFIED ON PLANS. ETC.
  
 13- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 14-16 OK.
  
 ORIGINAL COMMENT:
 17- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 DRAFSTOPPING IN AREAS AS REQUIRED BY SEC. R302.12
 FBC-RESIDENTIAL.
  
 RESPONSE:
 DRAFSTOPPING AND FIREBLOCKING ARE TWO DIFFERENT
 REQUIREMENTS. 2ND FLOOR FRAMING PLAN HAS A NOTE TO
 "PROVIDE DRAFSTOPPING BELOW STAIRS AT STAIR OPENING".
 FIREBLOCKING IS REQUIRED IN STAIRS CONCEALED SPACES.
 SEE SEC. R302.11 FBC-RESIDENTIAL. ON THE OTHER HAND
 DRAFSTOPPING IS ONLY REQUIRED IN FLOOR-CEILING
 ASSEMBLIES. SEE SEC. R302.12 FBC-RESIDENTIAL. REVISE AS
 REQUIRED.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  