| 2021-12-15 16:11:34 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC SEVENTH EDITION (2020) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THE DRAWINGS FROM THE ENGINEER ARE NOT SIGNED AND |
| | SEALED. ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED |
| | TO HAVE THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE |
| | ON THEM. YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED |
| | AND SEALED PAPER VERSION OF DRAWINGS. AFTER THE |
| | ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE |
| | CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT |
| | TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S ORIGINAL |
| | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE |
| | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE |
| | SIGNATURE ARE ACCEPTABLE. FS 481 & 61G1 OR FS 471 & |
| | 61G15 |
| | |
| | 2) THE DEFAULT EXPOSURE CATEGORY IS C. IF YOU WISH TO |
| | USE EXPOSURE CATEGORY B YOU WILL NEED TO SUBMIT AN |
| | ANALYSIS FROM THE ENGINEER THAT SHOWS THAT THIS PROJECT |
| | SHOULD BE CONSIDERED EXPOSURE B. FBC 1609.4.3 THE |
| | COMPONENT AND CLADDING WIND PRESSURES WILL NEED TO BE |
| | INCREASED TO EXPOSURE C VALUES. THE EFFECTIVE WIND AREA |
| | FOR THE STOREFRONT DOOR OPENING IS 60 SQFT. |
| | |
| | 3) PROVIDE A WALL SECTION TO SHOW THE EXTERIOR WALL |
| | SHEATHING, THE WALL INSULATION, THE VAPOR BARRIER, THE |
| | BOND BREAK BETWEEN THE STUCCO AND THE VAPOR BARRIER, |
| | THE WIRE LATH AND THE STUCCO AND THE INTERIOR WALL |
| | COVERING. FBC 107.2.1 & CHAPTER 7 |
| | |
| | 4) SUBMIT PRODUCT APPROVALS FOR THE STOREFRONT, |
| | STOREFRONT WINDOWS AND THE STOREFRONT DOOR. FBC 107.3.4 |
| | - PROVIDE TWO SETS OF PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC 61G20-3.001 PER |
| | FLORIDA STATUTE 553.842 (5) THAT HAVE BEEN REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD. PROVIDE |
| | TWO COMPLETE PRODUCT APPROVALS WITH FL OR NOA NUMBERS |
| | INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN |
| | PRESSURES FOR EACH OF THE DIFFERENT ROOFING MATERIALS, |
| | WINDOW (GLASS TYPES), STRUCTURAL MULLIONS AND EXTERIOR |
| | DOOR TYPES. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR |
| | ELECTRONICALLY SUBMITTED DOCUMENTS. |
| | |
| | 5) IF THE STOREFRONT GLAZING IS NOT IMPACT RATED SUBMIT |
| | THE PRODUCT SPPROVALS AND INSTALLATION INSTRUCTIONS FOR |
| | THE IMPACT PROTECTION DEVICES. FBC 1609.1.2 |
| | |
| | 6) THE VALUATION STATED ON THE PERMIT APPLICATION OF |
| | $2300.00 IS TOO LOW FOR THIS PROJECT. THE COSTS OF ALL |
| | MATERIALS, LABOR, ENGINEERING FEES, OVERHEAD AND PROFIT |
| | NEED TO BE INCLUDED IN THE VALUATION. BUILDING PERMIT |
| | VALUATION. FOR PERMITTING PURPOSES, VALUATION OF FBC |
| | 109.3 BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT |
| | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, |
| | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, |
| | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, |
| | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY |
| | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT |
| | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
| | |
| | 7) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH |
| | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. |
| | |
| | |
| | |
| | |
| | |