| Date |
Text |
| 2021-10-05 10:57:10 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #21091314 |
| | |
| | NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK |
| | SHALL COMPLY WITH THE MATERIALS AND METHODS |
| | REQUIREMENTS IN THE FLORIDA BUILDING CODE. |
| | |
| | 1- PROVIDE COMPLETE PRODUCT APPROVALS FOR THE SHINGLES, |
| | SHINGLES UNDERLAYMENT AND FLAT ROOF. ONLY THE FLORIDA |
| | PRODUCT APPROVAL COVER PAGE WAS SUBMITTED. NEED TO |
| | SUBMIT THE INSTALLATION INSTRUCTIONS ALSO. |
| | FAC G20-3.001 |
| | |
| | 2- FLAT ROOF PRODUCT APPROVAL SUBMITTED: |
| | CLEARLY MARK WHICH APPROVED ASSEMBLY IS GOING TO BE |
| | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN |
| | PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. NOTE: IF THE |
| | SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES FOR |
| | ALL ROOF ZONES, THEN SIGNED AND SEALED RAS 117 |
| | CALCULATIONS ARE REQUIRED. |
| | SEC. R301.2.1 FBC-RESIDENTIAL. |
| | |
| | 3- SHINGLES UNDERLAYMENT PRODUCT APPROVAL SUBMITTED: |
| | PROVIDE SPECIFICATIONS CLEARLY SHOWING HOW COMPLYING |
| | WITH THE NEW 2020 CODE REQUIREMENT FOR ROOFING |
| | UNDERLAYMENT SEC. 1507.1.1.1 FBC-BUILDING. |
| | NOTE: CLEARLY MARK WHICH UNDERLAYMENT IS GOING TO BE |
| | USED. |
| | |
| | 4- NEED TO SPECIFY THE MEAN ROOF HEIGHT, ROOF PITCH, AS |
| | REQUIRED BY THE CITY POLICY FOR ALL ROOFING PERMITS. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 5- PROVIDE ROOF SKETCH SHOWING ALL THE FLAT AND PITCHED |
| | ROOF AREAS. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |