| 2021-10-27 16:29:32 | FAILED |
| | |
| | 1) RESOLUTION NO. 256-21 REQUIRES THAT PRIOR TO THE |
| | ISSUANCE OF A BUILDING PERMIT FOR THE CONSTRUCTION OF |
| | THE BJ'S WHOLESALE CLUB BUILDING, VERIFICATION MUST BE |
| | PROVIDED TO THE PLANNING DIVISION THAT FLORIDA POWER & |
| | LIGHT AND BELLSOUTH HAVE RELEASED OR RELOCATED THE |
| | EXISTING EASEMENTS WHICH CONFLICT WITH THE PROPOSED |
| | BUILDING. ZONING WILL NOT APPROVE THE PERMIT UNTIL THE |
| | VERIFICATION HAS BEEN PROVIDED. |
| | |
| | 2) THE PROPERTY WAS RECENTLY SUBDIVIDED BY THE |
| | RECORDATION OF THE PLAT ENTITLED BRANDSMART EXECUTIVE |
| | CENTER. PRIOR TO ZONING APPROVAL OF THIS BUILDING |
| | PERMIT, PROVIDE THE PLANNING DIVISION A COPY OF THE |
| | RECORDED CROSS ACCESS, PARKING, DRAINAGE, ETC AND |
| | MAINTENANCE AGREEMENTS FOR THE AREA COVERED BY THE |
| | PLAT. |
| | |
| | 3) PROVIDE A SURVEY FOR THE SITE WHICH SHOWS THE |
| | PROPOSED BUILDING LOCATION AND THE BUILDING SETBACKS. |
| | |
| | 4) RESOLUTION NO. 256-21 APPROVED THE BUILDING SQUARE |
| | FOOTAGE AT 103,611 SQUARE FEET. THE PALM BEACH COUNTY |
| | TRAFFIC APPROVAL LETTER APPROVED 103,607 SQUARE FEET. |
| | THE PLANS SHOW A 105,568 SQUARE FOOT BUILDING, WHICH |
| | EXCEEDS THE AMOUNT THAT WAS APPROVED. IT APPEARS THAT |
| | THIS IS DUE TO THE ADDITION OF THE MEZZANINE SPACE. THE |
| | BUILDING SQUARE FOOTAGE MAY NOT EXCEED THE APPROVALS. |
| | |
| | 5) SHEET A102 SHOWS A BOLLARD BEING INSTALLED AT THE |
| | END OF THE LOADING DOCK SCREEN WALL. THE DRIVE AISLE |
| | DIMENSIONS ON THE APPROVED SITE PLAN WERE PROVIDED FROM |
| | THE END OF THE SCREEN WALL (NO BOLLARD WAS SHOWN). |
| | PROVIDE A DRAWING SHOWING THE DRIVE AISLE DIMENSION |
| | WHEN MEASURED FROM THE PROPOSED BOLLARD SO THAT STAFF |
| | CAN VERIFY THAT THE DRIVE AISLE STILL HAS ADEQUATE |
| | CLEARANCE FOR TWO-WAY TRUCK TRAFFIC. |
| | |
| | 6) THE ARCHITECTURAL SITE PLAN DOES NOT ACCURATELY |
| | DEPICT THE PARKING ALONG THE NORTH SIDE OF THE |
| | BUILDING. THERE ARE ONLY TWO PARKING SPACES PERMITTED |
| | WEST OF THE DOOR WITH THE STRIPED AREA DUE TO THE WIDTH |
| | OF THE DRIVE AISLE. ADDITIONALLY, THE MAIN PARKING |
| | FIELD IS ALSO NOT IN COMPLIANCE WITH THE APPROVED |
| | PLANS. ALL PLANS MUST SHOW THE ACCURATE APPROVED |
| | CONDITIONS. |
| | |
| | 7) THE UNDERGROUND CONDUITS TO THE GAS STATION ARE NOT |
| | PERMITTED TO BISECT THE TERMINAL OR INTERIOR LANDSCAPE |
| | ISLANDS. THEY MUST BE RELOCATED. |
| | |
| | 8) RESOLUTION NO. 256-21 REQUIRES THAT ALL ROOFTOP |
| | MECHANICAL EQUIPMENT MUST BE SCREENED TO THE FULL |
| | HEIGHT OF THE EQUIPMENT. PROVIDE CROSS SECTION OR |
| | ELEVATION DRAWINGS THAT SHOW THE FULL HEIGHT OF THE |
| | ROOFTOP MECHANICAL EQUIPMENT, INCLUDING CURBS, AND THE |
| | METHOD OF SCREENING. |
| | |
| | 9) THE LOW TOWER ELEMENTS MUST BE A COMPLETE HIP ROOF, |
| | NOT JUST THE TRUNCATED HALF PORTION ON THE EXTERIOR |
| | BUILDING FACADE AS SHOWN ON THE PLANS. ADDITIONALLY, |
| | PLEASE CHECK THE ELEVATION DRAWINGS AS THERE ARE |
| | DISCREPANCIES ON THE LOW TOWER LOCATIONS (MORE SEEM TO |
| | BE SHOWN THAN ARE BEING INSTALLED). |
| | |
| | 10) SEPARATE PERMITS ARE REQUIRED FOR: |
| | |
| | A. PARKING LOT |
| | B. SITE LIGHTING |
| | C. SIGNAGE |
| | D. WALLS |
| | E. BICYCLE RACKS |
| | F. HARDSCAPE |
| | |