| Plan Review Notes For Permit 21091154 |
| Permit Number |
21091154 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-10-19 07:23:22 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 21091154 | | | 10/18/2021 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEETS P2 & P4: PROVIDE EQUIPMENT SCHEDULES AND | | | SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE NEW DRAIN | | | PUMP AND WASTE EVAC UNIT- SECTIONS 712.1 & 713.1 FBC P. | | | | | | 2) P2 & P4: PROVIDE AN ENLARGED PIPING DRAWING FOR THE | | | DRAIN PUMP SHOWING THE LOCATIONS OF THE REQUIRED FULL | | | OPEN VALVE AND CHECK VALVE- SECTION 712.2. FBC P. SHOW | | | ALL COMPONENTS OF THE SYSTEM WILL BE IN ACCESSIBLE | | | LOCATIONS. | | | | | | 3) P2 & P4: PLEASE REFER TO SECTIONS 713.4- 713.7 FBC | | | P. AND PROVIDE MORE INFORMATION ABOUT THE WASTE EVAC | | | UNIT. INDICATE THE PURPOSE OF THE UNIT, AND WHAT TYPE | | | OF FLUIDS WILL BE DRAINED THROUGH IT. IS THE UNIT A | | | COMPONENT OF A LARGER VACUUM SYSTEM? | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|