| 2022-02-17 08:43:33 | 2ND REVIEW FBC-2017 PLUMBING |
| | PERMIT- 21091144 |
| | 2/17/2022 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 |
| | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| | 2017 |
| | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| | EDITION 2017 |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) AS PREVIOUSLY NOTED IN 1ST REVIEW COMMENT #1C COPIED |
| | BELOW, THE POOL WATER (INCLUDING RECIRCULATION SYSTEM |
| | BACKWASH) SHALL NOT DRAIN INTO THE SANITARY SYSTEM. ALL |
| | POOL WASTE WATER SHALL DRAIN INTO THE STORM SYSTEM AND |
| | BE DECHLORINATED PRIOR TO DRAINING INTO THE SYSTEM. WPB |
| | GUIDELINES FOR WASTE WATER DISPOSAL ARE COPIED BELOW. |
| | THE CORRECTED PLANS DO NOT SHOW DECHLORINATION FOR THE |
| | POOL LEAKAGE WATER, AND ARE STILL SHOWING THE BACKWASH |
| | DRAINING INTO SANITARY SYSTEM. PLEASE CONTACT THE |
| | PARTIES LISTED IN THE GUIDELINES FOR FURTHER |
| | INFORMATION. |
| | |
| | 1ST REVIEW- 1C) THE PLAN SHOWS THE POOL WATER LEAKAGE |
| | WILL DRAIN INTO THE POOL EQUIPMENT ROOM. THERE ARE TWO |
| | HUB DRAINS IN THE ROOM DEDICATED TO STORM AND TO |
| | SANITARY. PLEASE NOTE THAT POOL WASTE WATER SHALL NOT |
| | DRAIN INTO THE SANITARY SYSTEM. AN ALTERNATE MEANS MUST |
| | BE PROVIDED FOR BOTH THE EMERGENCY POOL DRAINAGE AND |
| | THE POOL BACKWASH- SEC. 90- 126(5) WPB MUNI. CODE OF |
| | ORDINANCES. PLEASE NOTE THAT ONLY DECHLORINATED POOL |
| | WASTE SHALL DRAIN INTO THE CITY STORM DRAIN SYSTEM- |
| | SECTION 90-205 EXCEPTION 1. |
| | |
| | SWIMMING POOL WATER MAY BE DISCHARGED TO THE CITY |
| | STORMWATER SEWER ONLY IF THE WATER IS DECHLORINATED |
| | ACCORDING TO SECTION 90-205(1) OF THE CITY OF WEST PALM |
| | BEACH CODE OF ORDINANCES. SUBMIT THE MANUFACTURER'S |
| | SPECIFICATION FOR THE DECHLORINATION SYSTEM FOR REVIEW |
| | AND STAMPING BEFORE THE INSPECTION. AT THE TIME OF POOL |
| | WATER DISCHARGE, THE FOLLOWING WILL BE REQUIRED: |
| | THE RECEIVING INLET MUST BE PROTECTED (FILTER CLOTH TO |
| | KEEP EXCESS SEDIMENTS FROM ROADWAY WASHING INTO THE |
| | INLET). |
| | NO DISCHARGE HOSE CAN BE DIRECTLY INSERTED INTO THE |
| | INLET TO DISCHARGE EFFLUENT. |
| | WHENEVER POSSIBLE, DISCHARGE EFFLUENT SHALL BE ALLOWED |
| | TO FILTER THROUGH GRASS AREA ON THE POOL OWNER'S |
| | PROPERTY BEFORE DISCHARGING ON CITY PROPERTY. |
| | DISCHARGE SHALL NOT FLOOD STREETS OR NEIGHBORING |
| | PROPERTY. |
| | FOR TECHNICAL QUESTIONS, CONTACT O&M SUPERINTENDENT |
| | STEPHON HARRIS AT [email protected] OR 561-822-2168. |
| | FOR STORMWATER DISCHARGE COMPLIANCE QUESTIONS, PLEASE |
| | CONTACT CHRIS JACKSON, ENVIRONMENTAL COMPLIANCE |
| | SPECIALIST III, PUBLIC UTILITIES DEPARTMENT, (561) |
| | 822-2062 [email protected], OR STORMWATER ENGINEER |
| | TRACEY WARD- 561-493-4787. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |
| | |