| Date |
Text |
| 2021-11-14 09:27:18 | BUILDING PLAN REVIEW |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | NFPA 70 2017 EDITION NEC 2017 |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | |
| | 1) VALUE |
| | CITY OF WPB CHPT. 1 VALUE |
| | 109.3 BUILDING PERMIT VALUATIONS. |
| | |
| | 1A. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE |
| | OF WORK. |
| | 1B. THE PERMIT VALUATION AND PERMIT FEE MUST BE |
| | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED |
| | CONTRACTOR WOULD PROVIDE. THIS INCLUDES ALL LABOR, |
| | MATERIALS AND RENTALS OF EQUIPMENT TO PERFORM THE SCOPE |
| | OF WORK. |
| | 1C. YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY |
| | THE OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT |
| | RENTAL TO VERIFY VALUE. |
| | |
| | PLEASE INCREASE THE VALUATION ACCORDINGLY. |
| | |
| | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE |
| | BUILDING OFFICIAL |
| | |
| | 2. DECK DESIGN SHAL BE PER FBC R507. |
| | R507.3DECK FOOTINGS. |
| | R507.4DECK POSTS. |
| | R507.4.1DECK POST TO DECK FOOTING. |
| | R507.5DECK BEAMS. |
| | R507.5.1DECK POST TO DECK BEAM. |
| | R507.6DECK JOISTS. |
| | R507.6.1LATERAL RESTRAINT AT SUPPORTS. |
| | R507.6.2DECK JOIST AND DECK BEAM BEARING. |
| | R507.7DECKING. |
| | R507.8VERTICAL AND LATERAL SUPPORTS. |
| | R507.8.2DECK LATERAL LOAD CONNECTION. |
| | |
| | 3. STAIRS |
| | |
| | R311.7.5.1 RISERS. |
| | THE MAXIMUM RISER HEIGHT SHALL BE 73/4 INCHES (196 MM). |
| | THE RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING |
| | EDGES OF THE ADJACENT TREADS. THE GREATEST RISER HEIGHT |
| | WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE |
| | SMALLEST BY MORE THAN 3/8 INCH (9.5 MM). RISERS SHALL |
| | BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE NOSING |
| | OF THE TREAD ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES |
| | (0.51 RAD) FROM THE VERTICAL. OPEN RISERS ARE PERMITTED |
| | PROVIDED THAT THE OPENING BETWEEN TREADS DOES NOT |
| | PERMIT THE PASSAGE OF A 4-INCH-DIAMETER (102 MM) |
| | SPHERE. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |
| | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | PLEASE UPLOAD YOUR DOCUMENTS TO PROJECT DOX. DO NOT |
| | E-MAIL DOCUMENTS TO THE PLANS EXAMINER. |
| | |
| | |