Plan Review Notes
Plan Review Notes For Permit 21091133
Permit Number 21091133
Review Stop P
Sequence Number 1
Notes
Date Text
2021-10-21 11:55:191ST REVIEW FBC-2020 RES.
 PERMIT- 21091133
 10/21/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P1: IT APPEARS THAT THE KITCHEN SINK HAS BEEN
 MISLABELED AS LAV IN THE RISER DIAGRAM- PLEASE CORRECT-
 - SECTION 107.2.1 WPB.
 2) P1: PLEASE ADD THE WASHING MACHINE DRAIN AND VENT
 PIPE SIZES TO THE RISER- SECTION 107.3.5.3 WPB, AND
 SECTION 406.2 FBC P. PLEASE NOTE A 2-INCH STANDPIPE
 CONNECTING TO A 3-INCH STACK OR BRANCH DRAIN IS
 REQUIRED.
 3) P1: PLEASE ADD THE 1/4 IN. PER FT. FINISH FLOOR
 SLOPE TO THE SHOWER DETAIL- SECTION P2709.1 FBC RES.
 4) P1: PROVIDE A SLAB REPAIR DETAIL- SECTION 107.2.1
 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  