| Date |
Text |
| 2021-10-20 15:04:15 | FAILED |
| | |
| | 1) THE CITYPLACE RETAIL MANAGEMENT APPROVAL STAMP IS |
| | REQUIRED ON THE PLANS. ALTERNATIVELY, YOU MAY PROVIDE A |
| | LETTER FROM CITYPLACE RETAIL MANAGEMENT WHICH APPROVES |
| | THE SPECIFIC PLANS SUBMITTED AS PART OF THE PERMIT. |
| | |
| | ARCADE IDENTITY SIGN TYPE 1D - STOREFRONT TYPE 1 |
| | |
| | 2) THE PROPOSED SIGN IS USING OPTION D ? SIGN MOUNTED |
| | TO RACEWAYS SPANNING THE VERTICAL COLUMNS. |
| | |
| | A. THE ROSEMARY SQUARE TENANT SIGN CRITERIA PROHIBIT |
| | ARCADE IDENTITY SIGNS FROM EXTENDING PAST THE WIDTH OF |
| | THE ARCADE OPENING. |
| | |
| | B. OPTION D ONLY PERMITS LETTERS TO BE MOUNTED TO THE |
| | RACEWAY, NOT MOUNTED TO A BACKER PANEL THAT IS MOUNTED |
| | TO A RACEWAY. NOTE: LETTERS MOUNTED TO A BACKER PANEL |
| | ARE ONLY PERMITTED AS OPTION C, WHICH REQUIRES THE |
| | PANEL TO BE MOUNTED TO SUPPORTS SUSPENDED FROM TOP OF |
| | THE ARCADE OPENING. |
| | |
| | 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | THAT THE SIGN AREA INCLUDE ALL ELEMENTS OF THE SIGN, TO |
| | INCLUDE THE BACKER PANEL. PROVIDE THE FULL VERTICAL |
| | DIMENSION OF THE SIGN. |
| | |
| | 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | THAT REVERSE CHANNEL LETTERS ARE FABRICATED OUT OF |
| | ALUMINUM WITH A MINIMUM METAL THICKNESS OF .060 INCHES. |
| | THE RETURNS DO NOT MEET THIS REQUIREMENT. |
| | |
| | 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA DO NOT |
| | SPECIFICALLY PERMIT LEXAN AS A SIGN MATERIAL; |
| | THEREFORE, THIS USE OF ALTERNATIVE MATERIALS ON THE |
| | SIGN REQUIRES A WAIVER I WRITTEN APPROVAL FROM |
| | CITYPLACE RETAIL TO BE SUBMITTED WITH THE PERMIT. |
| | |
| | 6) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | THAT RIVETS, SCREWS AND OTHER FASTENERS THAT EXTEND TO |
| | VISIBLE SURFACES SHALL BE FLUSH, FILLED AND FINISHED SO |
| | AS TO BE UNNOTICEABLE. THE BOLT ENDS/NUTS THAT EXTEND |
| | PAST THE BACKER PANEL DO NOT MEET THIS STANDARD. IF THE |
| | BOLT ENDS/NUTS MUST EXTEND PAST THE BACKER PANEL, THEY |
| | NEED TO BE CONCEALED BY CAPS MATCHING THE COLOR OF THE |
| | MOUNTING PLATE. |
| | |
| | 7) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT A |
| | MAXIMUM LETTER HEIGHT OF 18 INCHES FOR A ARCADE |
| | IDENTITY SIGN. PROVIDE THE FULL DIMENSION OF THE "T" |
| | AND THE "G" ("G" DIMENSION PROVIDED DOES NOT CLEARLY |
| | SHOW THE FULL HEIGHT). |
| | |
| | 8) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE ALL |
| | CONDUIT, RACEWAYS, WIRING, BALLAST BOXES, TRANSFORMERS, |
| | JUNCTION BOXES, BELL BOXES, POWER SUPPLY AND OTHER |
| | EQUIPMENT NECESSARY FOR SIGN CONNECTION SHALL BE |
| | CONCEALED AND NOT VISIBLE TO THE PUBLIC. NOTE: EXPOSED |
| | CONDUIT, EVEN IF PAINTED, ATTACHED TO THE COLUMN AND |
| | INSIDE OF THE FASCIA DOES NOT MATCH THIS REQUIREMENT. |
| | |
| | PERMITTED SIGN SIZE: 30.3 SF |
| | PROPOSED SIGN SIZE: UNKNOWN |
| | |
| | BLADE SIGN |
| | |
| | 9) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | THAT BLADE SIGNS BE MOUNTED WITHIN THE TENANT'S LEASE |
| | LINE. THE ELEVATION DRAWING SHOWS THE BLADE SIGN |
| | OUTSIDE OF THE SWEETGREEN LEASE LINE. |
| | |
| | 10) THE ROSEMARY SQUARE TENANT SIGN CRITERIA LIMIT THE |
| | SIGN COPY TO TRADE NAMES ONLY. THE USE OF THE LOGO "SG" |
| | IS ONLY PERMITTED AS A WAIVER I. A WAIVER I REQUIRES |
| | WRITTEN APPROVAL FROM CITYPLACE RETAIL. |
| | |
| | 11) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| | THAT THE SIGN COPY AREA SHALL MAINTAIN A MARGIN AT |
| | LEAST THREE (3) INCHES FROM ANY EDGE OF THE PERCEIVED |
| | SIGN AREA. PROVIDE VERTICAL DIMENSION FROM EITHER SIDE |
| | OF THE LETTERS TO THE EDGE OF THE SIGN FACE THAT |
| | VERIFIES THIS REQUIREMENT. |
| | |
| | 12) PROVIDE VERIFICATION THAT THE DEDICATED PRIMARY |
| | SIGN CIRCUIT AND DISCONNECT ARE BEHIND THE WALL WITHIN |
| | THE STORE AND THE WIRING FROM THOSE TO THE SIGN WILL BE |
| | THROUGH THE WALL TO THE INTERNAL POWER SUPPLY AND NOT |
| | VISIBLE TO THE PUBLIC IN ACCORDANCE WITH THE ROSEMARY |
| | SQUARE TENANT SIGN CRITERIA. THIS MAY BE DONE AS A NOTE |
| | ON THE PLANS. |
| | |
| | CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| | [email protected] |