Plan Review Notes
Plan Review Notes For Permit 21090944
Permit Number 21090944
Review Stop B
Sequence Number 1
Notes
Date Text
2021-10-25 11:53:51OFFICE BUILDOUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
 1) PLEASE SHOW THE WALL FINISH AROUND THE MOP SINK TO
 COMPLY WITH FBC 1210.2.2 WALLS AND PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR, (DRYWALL IS NOT
 CONSIDERED A HARD SURFACE)
  
 2) WALLS SHOWN IN DETAILS 4 AND 5 ON DRAWING A1.31 -
 SHOWS PAINT ON THE DRYWALL (DRYWALL IS NOT CONSIDERED A
 HARD SURFACE) FBC 1210.2.2 WALLS AND PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR,
  
 3) PLEASE PROVIDE THE RAISED FLOOR DETAILS -
 MANUFACTURE SPECS. FBC 107.2.1
  
 4) PLEASE SHOW THE TOILET PAPER DISPENSER LOCATION FROM
 THE FRONT OF THE TOILET PER FBC 604.7 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.
  
 5) THE 18 INCH VERTICAL GRAB BAR IS NOT REQUIRED PER
 FBC - PLEASE SHOW THE REQUIRED 12 INCHES CLEARANCE
 BETWEEN THE TOP OF THE GRAB BAR AND PROTRUDING OBJECTS
 ABOVE THE HORIZONTAL GRAB BAR - FBC 609.3 THE SPACE
 BETWEEN THE GRAB BAR AND PROJECTING OBJECTS ABOVE SHALL
 BE 12 INCHES (305 MM) MINIMUM.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved