| Date |
Text |
| 2021-10-14 11:51:23 | NEW PAVILION |
| | REVIEWED BY ROGER MCPHERSON |
| | 561-805-6716 |
| | [email protected] |
| | CODE USED FOR REVIEW - 2020 FBC WITH 2017 WPB CHAPTER 1 |
| | AMENDMENT |
| | |
| | CORRECTIONS NEEDED - |
| | 1) PLEASE PROVIDE A SITE PLAN SHOWING THE FOLLOWING |
| | INFORMATION 107.2.5 SITE PLAN. THE CONSTRUCTION |
| | DOCUMENTS SUBMITTED WITH THE APPLICATION FOR PERMIT |
| | SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE |
| | THE SIZE AND LOCATION OF NEW CONSTRUCTION AND EXISTING |
| | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE |
| | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED |
| | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS |
| | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN |
| | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE |
| | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE |
| | SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED |
| | WATER RETAINING SWALES) |
| | |
| | 2) PLEASE PROVIDE A SURVEY. |
| | |
| | 3) PLEASE SHOW THE SIDING DETAILS - ATTACHMENT FASTENER |
| | SIZE AND ON CENTER SPACING - OR PROVIDE A MIAMI DADE OR |
| | FLORIDA STATE PRODUCT APPROVAL - TO MEET THE REQUIRED |
| | WIND LOADS FBC 1405.16 |
| | |
| | 4) PLEASE PROVIDE A SOIL REPORT (GEOTECHNICAL REPORT) |
| | FBC 1803.2 |
| | |
| | 5) PLEASE SHOW THE TRUSS STRAPPING DESIGNATION NUMBER |
| | AND SIZE AND NUMBER OF FASTENERS TO MEET THE UPLIFT |
| | REQUIREMENTS. FBC 1609.1 |
| | |
| | 6) PLEASE PROVIDE THE ROOFING SHINGLE PRODUCT APPROVAL |
| | - ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED |
| | APPROVED BY THE DESIGNER OF RECORD FBC WPB 107.3.4 |
| | |
| | 7) ROOFING UNDERLAYMENT SHOWN FOR THE SHINGLE ROOF |
| | NEEDS TO MEET THE REQUIREMENTS OF FBC 1507.1.1 |
| | |