| Date |
Text |
| 2021-09-29 15:33:12 | 1ST REVIEW FBC-2020 PLUMBING |
| | PERMIT- 21090540 |
| | 9/28/2021 |
| | |
| | CODES IN EFFECT: |
| | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) FAIR HOUSING ACT COMPLIANCE: THE CONDOMINIUMS AT TWO |
| | CITY PLAZA- 701 S. OLIVE AVE. WERE DESIGNED AND |
| | CONSTRUCTED IN COMPLIANCE THE FAIR HOUSING ACT DESIGN |
| | MANUAL. THE PROPOSED ALTERATIONS TO THE KITCHEN AND |
| | BATHROOM IN UNIT 910 SHALL ALSO BE IN COMPLIANCE. |
| | PLEASE PROVIDE CODE DATA INFORMATION ON SHEET 1 THAT |
| | INCLUDES COMPLIANCE WITH THE FAIR HOUSING ACT DESIGN |
| | MANUAL AND THE CURRENT FLORIDA BUILDING CODES- 2020 7TH |
| | EDITION. THE FAIR HOUSING ACCESSIBILITY GUIDELINES ARE |
| | INCLUDED IN THE FLORIDA ACCESSIBILITY CODE- 2020 7TH |
| | EDITION AND THE FAIR HOUSING DESIGN ACT MANUAL. |
| | |
| | A) SHEET 1 & 2: THE DESIGN PROFESSIONAL OF RECORD SHALL |
| | INDICATE ON THE PLAN WHICH OF THE TWO BATHROOM TYPES IS |
| | THE BASIS OF DESIGN- SPECIFICATION TYPE A OR B ON THE |
| | PLANS. PLEASE REFER TO PAGES 7.34- 7.39 OF THE DESIGN |
| | MANUAL FOR EXPLANATORY INFORMATION ON SPECIFICATION A & |
| | B AND SHOW COMPLIANCE. |
| | B) SHEET 1 & 2: REFER TO CHAPTER 7 (REQUIREMENT 7 |
| | USABLE KITCHENS & USABLE BATHROOMS) AND PROVIDE |
| | ENLARGED BATHROOM AND KITCHEN DRAWINGS AND DETAILS. |
| | BASED ON THE DESIGN SPECIFICATIONS PLEASE PROVIDE |
| | DETAILS AND NOTES IN COMPLINACE WITH THE CODE SECTIONS |
| | LISTED BELOW. |
| | PAGES 7.1- 7.6 CLEAR FLOOR SPACES FOR SINKS AND |
| | APPLIANCES |
| | PAGES 7.7- 7.11 CLEARANCES BETWEEN KITCHEN COUNTERS AND |
| | ALL OPPOSING ELEMENTS. |
| | PAGES 7.12- 7.16 REMOVABLE SINK AND APPLIANCE CABINET |
| | DOORS INCLUDING KNEE SPACES. |
| | PAGES 7.40-7.46 WATER CLOSET CLEAR FLOOR SPACES. |
| | PAGES 7.47- 7.52: LAVATORY AND VANITY CLEAR FLOOR AND |
| | KNEE AND TOE CLEARANCES. |
| | PAGES 7.53- 7.55: BATHTUB CLEAR FLOOR SPACE AND CONTROL |
| | LOCATIONS |
| | C) SHEET 1 & 2: REFER TO CHAPTER 6 (REINFORCED WALLS |
| | FOR GRAB BARS). BASED ON CHAPTER 7 COMPLIANCES LISTED |
| | ABOVE, PLEASE PROVIDE DRAWINGS AND DETAILS SHOWING GRAB |
| | BAR REINFORCEMENT LOCATIONS AND INSTALLATION DETAILS. |
| | PAGES 6.3- 6.8- WATER CLOSETS |
| | PAGES 6.8- 6.11 BATHTUBS |
| | PAGES 6.14- 6.16 REINFORCEMENT METHODS |
| | |
| | PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE |
| | GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND |
| | DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE |
| | A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE |
| | ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET |
| | THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY |
| | GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO |
| | REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF |
| | REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN, |
| | PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A |
| | COPY OF THE FAIR HOUSING AFFIDAVIT. |
| | |
| | 2) SHEET 2: SHOW THE WATER LINE RUN TO THE REFRIGERATOR |
| | ICE MAKER, AND INDICATE A WATER HAMMER ARRESTOR AND |
| | BACKFLOW PREVENTER WILL BE INSTALLED- SECTION 604.9 & |
| | 608.3 FBC P. |
| | |
| | 3) SHEET 2: PLEASE REMOVE THE BROWARD COUNTY AMENDMENTS |
| | REFERENCE SHOWN BELOW THE PLUMBING NOTES- SECTION |
| | 107.2.1 WPB. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |