| 2021-09-23 10:43:04 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE |
| | MARSHAL, WITH THE FOLLOWING COMMENTS: |
| | |
| | |
| | 1) THERE IS AN INDICATION OF REPLACING THE FLOORING |
| | HOWEVER THERE ARE NO SPEC SHEET FOR THE FLOOR |
| | UNDERLAYMENT, NOR ACTUAL PROPOSED FLOORING. |
| | |
| | TILE FLOORING COULD HAVE DIFFERENT MEANINGS AND IF NOT |
| | CERAMIC/PORCELAIN/MARBLE/CEMENT IT CAN BE |
| | VINYL/LAMINATE ETC AND IS MANUFACTURED |
| | AROUND THE WORLD AND NOT ALL ARE TESTED AND MEETING |
| | LISTED AND NFPA STANDARDS. |
| | |
| | FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE SPECIFIC |
| | FLOORING TYPE AND/OR PRODUCT SPEC SHEETS OF THE |
| | PROPOSED FINISHED FLOORING INDICATING THE FIRE BEHAVIOR |
| | RATING. |
| | |
| | |
| | 2) THE FLOOR PLAN SUBMITTED INDICATES THE LOCATION OF |
| | THE BATHROOM & KITCHEN THAT APPEAR TO BE LOCATED ALONG |
| | A |
| | FIRE RATED TENANT AND/OR CORRIDOR SEPARATION WALL |
| | REQUIRING MAINTENANCE/REPAIR OF THE FIRE RATED WALL |
| | SHOULD THE DEMO DAMAGE THAT WALL. |
| | |
| | PLEASE REVIEW, ENSURE WALL FIRE RATING IS NOT |
| | COMPROMISED AND PROVIDE A NOTE OF ACKNOWLEDGEMENT ON |
| | THE FLOOR PLAN. |
| | |
| | |
| | |
| | 3) PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND |
| | EQUIPMENT. |
| | |
| | DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM |
| | DEVICES/EQUIPMENT. |
| | |
| | THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT |
| | DEMO AND CONSTRUCTION. |
| | |
| | ALL FIRE SPRINKLER & FIRE ALARM WORK. INCLUDING DEMO, |
| | SHALL BE DONE UNDER SEPARATE PERMITS & SHOP DRAWINGS. |
| | |
| | |
| | PLEASE REVIEW, ENSURE COMPLIANCE AND PROVIDE A NOTE OF |
| | ACKNOWLEDGEMENT ON THE FLOOR PLAN. |
| | |
| | |
| | |
| | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE |
| | RE-SUBMITTAL OF THE ABOVE. |
| | |
| | |
| | PETER LEDUC |
| | FIRE MARSHAL |
| | 561-804-4709 |
| | [email protected] |