2021-10-14 16:16:54CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21090526 3200 45TH ST
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 A SEPARATE PERMIT IS REQUIRED FOR THE BACKFLOW
 PREVENTER AND MUST BE TESTED AND CERTIFIED BY THE CITY
 OF WEST PALM BEACH UTILITIES DEPT PER THE CITY OF WEST
 PALM BEACH CROSS CONNECTION CONTROL MANUAL
  
 A REVIEW OF MINIMUM PLUMBING FIXTURE REQUIREMENTS AS
 REQUIRED BY FBC ACC IS PART OF THE PLUMBING REVIEW
 PROCESS BUT IS TYPICALLY ADDRESSED ON THE ARCHITECTURAL
 PLANS. ANY COMMENTS CONCERNING THESE REQUIREMENTS MUST
 BE SATISFACTORILY ADDRESSED PRIOR TO A PLUMBING REVIEW
 APPROVAL.
  
 1.PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC ACC
 CHAPTERS 2, 3 AND 6, CLEARLY INDICATE ON ID101 PLAN AND
 ELEVATION DETAILS FOR NEW TOILET ROOM, THE FOLLOWING:
 A.THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR
 PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE
 OF THE WATER CLOSET SHALL BE 16 INCHES MINIMUM TO 18
 INCHES MAXIMUM FROM THE SIDE WALL OR PARTITION PER FBC
 ACC 604.2.
 B.CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES
 MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND
 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE REAR
 WALL PER FBC ACC 604.3.1
 C.THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 INCHES
 MINIMUM ON THE OTHER SIDE PER FBC ACC 604.5.2
 D.FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC.
 HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH 309.
 FLUSH CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE
 WATER CLOSET PER FBC ACC 604.6
 E.TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT
 OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE 15
 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR AND SHALL NOT BE LOCATED BEHIND GRAB BARS PER FBC
 ACC 604.8.
 F.THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH
 FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES
 (485 MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS
 SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION PER
 FBC ACC 604.4.
 G.PER FBC ACC 609.4, GRAB BARS SHALL BE INSTALLED IN A
 HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP (NOT
 THE CENTER) OF THE GRIPPING SURFACE,
 H.SHOW TOE AND KNEE CLEARANCE FOR THE LAVATORY AS
 REQUIRED BY FBC ACC 306.2 AND 306.3
 I.MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND.
 J.SHOW TURNING SPACE COMPLYING WITH FBC ACC 304.3.1 OR
 304.3.2.
 K.SHOW CLEAR FLOOR SPACES FOR DRINKING FOUNTAIN AND
 LAVATORY. THE CLEAR FLOOR OR GROUND SPACE SHALL BE 30
 INCHES (760 MM) MINIMUM BY 48 INCHES (1220 MM) MINIMUM
 AND COMPLY WITH FBC ACC SECTION 305.
  
 2.PER WPB FBC 107.2.1, TO SHOW COMPLIANCE WITH FBC ACC
 CHAPTERS 2, 3 AND 6, CLEARLY INDICATE ON ID101 PLAN AND
 ELEVATION DETAILS FOR DRINKING FOUNTAIN, THE FOLLOWING:
 A. DRINKING FOUNTAINS SHALL COMPLY WITH 307 AND 602 PER
 FBC ACC 602.1.
 B. PROTRUDING OBJECTS 307.2 PROTRUSION LIMITS 307.2.
 OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES AND NOT
 MORE THAN 80 INCHES ABOVE THE FLOOR SHALL NOT PROTRUDE
 MORE THAN 4 INCHES HORIZONTALLY INTO THE CIRCULATION
 PATH. DRINKING FOUNTAIN IS OUT OF COMPLIANCE.
 C. UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE
 COMPLYING WITH 305 POSITIONED FOR A FORWARD APPROACH
 AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED PER FBC ACC 602.2.
 D. SPOUT OUTLETS SHALL BE 36 INCHES (915 MM) MAXIMUM
 ABOVE THE FINISH FLOOR OR GROUND PER FBC ACC 602.4.
 E. SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING
 PERSONS SHALL BE 38 INCHES (965 MM) MINIMUM AND 43
 INCHES (1090 MM) MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND PER FBC ACC 602.7
 F.THE SPOUT SHALL BE LOCATED 15 INCHES (380 MM) MINIMUM
 FROM THE VERTICAL SUPPORT AND 5 INCHES (125 MM) MAXIMUM
 FROM THE FRONT EDGE OF THE UNIT, INCLUDING BUMPERS PER
 FBC ACC 602.5.
  
 3.PER FBC PL 310.3 AND FBC 1210.2.2, WALLS AND
 PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE SINKS,
 URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD,
 NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS THAN 4
 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR
 STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS
 SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY
 MOISTURE. PLEASE NOTE THAT FBC 1210.2.2 STIPULATES THAT
 THE MATERIAL BE "HARD." THE INTENT OF THIS SECTION IS
 THAT THE SURROUNDING MATERIAL SHOULD NOT BE OF A TYPE
 THAT IS EASILY DAMAGED SUCH THAT THE MATERIAL COULD
 BECOME ABSORBENT AND THUS, NOT READILY CLEANABLE AND
 SANITIZED. PAINTED DRYWALL, EVEN WHERE COATED WITH
 HIGHLY DURABLE PAINTS, DOES NOT MEET THE INTENT OF
 SECTION 1210.2.2. THE TYPICAL MATERIALS USED FOR THIS
 APPLICATION ARE CERAMIC TILE, FIBERGLASS REINFORCED
 PLASTIC (FRP) PANELS, PHENOLIC PANELS, LAMINATED
 PLASTIC PANELS, PAINTED STEEL AND STAINLESS STEEL.
  
 4. PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL.
  
 5. PER WPB FBC 107.2.1, PROVIDE WATER HEATER DETAIL-
 PROVIDE DETAIL OF WATER HEATER SHOWING HEATER W/STORAGE
 CAPACITY, PIPING INCLUDING CW, HW, VALVES (INCLUDING
 VACUUM RELIEF VALVE IF APPLICABLE FBC PL 504.2) ,
 THERMAL EXPANSION CONTROL DEVICE (INCLUDING SIZE), T&P
 DISCHARGE (INCLUDING TERMINATION) AND WATER HEATER PAN
 AND DRAIN (INCLUDING TERMINATION) PER WPB FPC 107.2.1;
 COMPLY WITH FBC PL 607.3, 503.1, 504.1, 504.4, 504.4.1,
 504.5, 504.6, 504.7, 504.7.1 AND 504.7.2.
  
 6. IF WATER HEATER IS SUSPENDED THEN PER WPB FBC
 107.2.1, PROVIDE DETAIL FOR SUPPORT OF SUSPENDED WATER
 HEATER
  
 7. PER WPB FBC 107.2.1, PROVIDE DISTANCE OF THE TWO-WAY
 CLEANOUT FROM THE FINISHED EXTERIOR WALL, SHOWING
 COMPLIANCE WITH FBC PL 701.8.3 AND 701.8.9; PLEASE NOTE
 THE CLEANOUT SHALL BE A MAXIMUM 10 FEET UPSTREAM OF THE
 JUNCTION OF THE BUILDING DRAIN(EXTENDS 30 INCHES BEYOND
 THE EXTERIOR WALL BY DEFINITION FBC PL CHAPTER 2) AND
 THE BUILDING SEWER AND MINIMUM 18 INCHES FROM THE WALL.
 ADDITIONALLY, A-101 DETAIL 13, INDICATES A BLOCK WALL
 WITH R5 INSULATION, METAL BUILDING GIRT AND 3-5/8 INCH
 FRAMING.
  
 8. PER WPB FBC 107.2.1, PROVIDE ON P1.11, A NOTE
 STATING ?TOILET ROOM FLOOR DRAIN COMMON VENTED BY THE
 DRINKING FOUNTAIN IN ACCORDANCE WITH FBC PL 911.3.?
  
 9. PER WPB FBC 107.2.1, PROVIDE ON P1.11, A NOTE
 STATING ?JANITOR ROOM FLOOR DRAIN AND MOP SINK VENTED
 IN ACCORDANCE WITH FBC PL 915.1, 915.2.2 AND 915.2.3.?
  
 10. PER WPB FBC 107.2.1, PROVIDE ON P1.11, THE
 ELEVATION OF THE VENT TERMINATION THROUGH THE EXTERIOR
 WALL ABOVE THE GROUND SHOWING COMPLIANCE WITH FBC PL
 903.6.
  
 11. PER WPB FBC 107.2.1 AND 107.3.5.1.3(13), PROVIDE A
 WATER RISER DIAGRAM.
  
 12. PER WPB FBC 107.2.1 AND 107.3.5.1.3(3), PROVIDE
 CALCULATIONS AND SIZING OF THE ROOF GUTTERS AND
 DOWNSPOUTS. SHOW COMPLIANCE WITH FBC PL 1106.3 AND
 1106.6.
  
 13.A-102 ROOF PLAN INDICATES THREE DOWNSPOUTS. C7
 DRAINAGE PLAN DOES NOT MATCH. PER WPB FBC 107.2.1,
 CLARIFY AND RECONCILE THE TWO DRAWINGS.
  
 14. PER WPB FBC 107.2.1, PROVIDE MINIMUM SLOPE
 REQUIREMENTS FOR HORIZONTAL SANITARY PIPING. SHOW
 COMPLIANCE WITH FBC PL 704.1.
  
 15.RE: P2.01 SANITARY AND DRAINAGE NOTES; FITTINGS FOR
 DRAINAGE CHANGE IN DIRECTION SHALL BE INSTALLED IN
 COMPLIANCE WITH FBC PL 706.3. PLEASE PER WPB FBC
 107.2.1, INDICATE THIS ON THE PLANS.
  
 16. RE: P2.01 VALVES NOTES; PER WPB FBC 107.2.1,
 PROVIDE NOTE ?ALL VALVES AND APPURTENANCES SHALL BE
 LEAD FREE.?
  
 17.PER WPB 107.2 AND FBC PL M314.2, PROVIDE A
 CONDENSATE DRAINAGE SYSTEM(S), PLAN VIEW FOR THE AIR
 HANDLERS. COMPLY WITH FBC PL SECTION 314. INCLUDE
 MATERIAL SPECIFICATION FOR PIPE AND INSULATION, DETAIL
 FOR TERMINATION TO EXTERIOR DRYWELL OR STORM. PLEASE
 NOTE THAT PER WPB CODE OF ORDINANCE CHAPTER 90, ARTICLE
 3, SECTION 90-12B5, A/C CONDENSATE (I INTERPRET THIS AS
 ANY CONDENSATION FROM EVAPORATOR COILS) SHALL NOT
 DISCHARGE TO THE CITY UTILITIES SANITARY SEWAGE
 INFRASTRUCTURE WITHOUT PERMISSION FROM THE UTILITIES
 DEPARTMENT.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21090526 3200 45TH ST
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved