Plan Review Notes
Plan Review Notes For Permit 21090349
Permit Number 21090349
Review Stop B
Sequence Number 2
Notes
Date Text
2021-10-01 08:16:59ROOFING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected].
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB 107.2.1.1
  
 1) IN THE PRODUCT APPROVAL PROVIDED FOR THE FLAT DECK -
 PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED IN THE
 ROOFING PRODUCT APPROVAL - ROOFING SYSTEM TO BE USED ON
 THE PROVIDED PRODUCT APPROVAL MAY REQUIRE ADDITIONAL
 SIGNED AND SEALED ATTACHMENT DETAILS FROM AN ARCHITECT
 OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH REQUIRE A
 HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE PRODUCT
 APPROVAL - SEE GENERAL NOTES ON THE PRODUCT APPROVAL.
 SIGNED AND SEALED DRAWINGS OR DOCUMENTS WILL NEED TO BE
 DIGITALLY SIGNED AND SEALED TO BE USED IN ELECTRONIC
 PLAN REVIEW. SHOW THE WIND DESIGN DATA USED ON THE
 ADDITIONAL ATTACHMENT DETAILS PER 2017 FBC AND ASCE
 7-10 - WIND SPEED - EXPOSURE - RISK CATEGORY - ETC.
  
 2) BOTH SHINGLE AND METAL ROOFING PRODUCT APPROVALS
 HAVE BEEN PROVIDED - WHICH ONE IS BEING INSTALLED?
  
 3) PLEASE PROVIDE THE ROOF HEIGHT AND THE ROOF SLOPE
 INFORMATION.
  