| 2021-09-22 13:58:18 | 09/22/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS | | | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | | TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | | | 1. WOULD YOU PLEASE PROVIDE A PLUMBING ISOMETRIC RISER | | | DIAGRAM FOR SANITARY AND WATER PER THE WPB AMENDMENTS | | | TO THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL PLUMBING. | | | | | | 2. HOT WATER LINES NOT IN CONDITION SPACE NEED TO BE | | | INSULATED WITH A MINIMUM R-3 PER THE 2020 FBC SEC. RE | | | 403.5.3. | | | | | | 3. IF THE TANK-LESS HAS A CONDENSATE IT NEEDS TO BE 1' | | | AWAY FROM THE STRUCTURE PER THE 2020 FBC SEC. R318.5. | | | | | | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA | | | | | | LUIS A. CRESPO | | | PLUMBING PLAN EXAMINER / INSPECTOR | | | EMAIL: [email protected] OFFICE: 561 805-6720 | | | |
|