| Date |
Text |
| 2021-09-23 15:58:18 | CODES IN EFFECT: |
| | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION |
| | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| | 6TH ED, CHAPTER 1 |
| | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| | MANUAL REVISED 2017 |
| | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 |
| | 7TH EDITION |
| | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION |
| | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH |
| | EDITION |
| | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION |
| | FAC= FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | |
| | 21090136 651 OKEECHOBEE BLVD 911 |
| | |
| | 1ST REVIEW |
| | PLUMBING COMMENTS: DENIED |
| | |
| | 1.RE: A-2; PER WPOB FBC 107.2.1, SHOWER VALVE NOTE |
| | SHALL REFERENCE FLORIDA PLUMBING CODE 2020 7TH EDITION |
| | SECTION 412.3, NOT THE FBC PLUMBING RESIDENTIAL |
| | P2303.6. |
| | |
| | 2.PER WPB FBC 107.2.1, PROVIDE THE FOLLOWING |
| | ?A) A SHOWER LINER/THRESHOLD DETAIL FOR THE SHOWER |
| | SHOWING COMPLIANCE WITH FBC PL 421.5.2. |
| | FLOORS UNDER SHOWER COMPARTMENTS, EXCEPT WHERE |
| | PREFABRICATED RECEPTORS HAVE BEEN PROVIDED, SHALL BE |
| | LINED AND MADE WATER TIGHT UTILIZING MATERIAL COMPLYING |
| | WITH SECTIONS 421.5.2.1 THROUGH 421.5.2.6. SUCH LINERS |
| | SHALL TURN UP ON ALL SIDES NOT LESS THAN 2 INCHES (51 |
| | MM) ABOVE THE FINISHED THRESHOLD LEVEL. LINERS SHALL BE |
| | RECESSED AND FASTENED TO AN APPROVED BACKING SO AS NOT |
| | TO OCCUPY THE SPACE REQUIRED FOR WALL COVERING, AND |
| | SHALL NOT BE NAILED OR PERFORATED AT ANY POINT LESS |
| | THAN 1 INCH (25 MM) ABOVE THE FINISHED THRESHOLD. |
| | LINERS SHALL BE PITCHED ONE-FOURTH UNIT VERTICAL IN 12 |
| | UNITS HORIZONTAL (2-PERCENT SLOPE) AND SHALL BE SLOPED |
| | TOWARD THE FIXTURE DRAINS AND BE SECURELY FASTENED TO |
| | THE WASTE OUTLET AT THE SEEPAGE ENTRANCE, MAKING A |
| | WATER-TIGHT JOINT BETWEEN THE LINER AND THE OUTLET. |
| | ?B) A DETAIL OF THE NICHE (IS THIS A BENCH) IN THE |
| | SHOWER STALL, SHOWING HOW IT WILL BE INCORPORATED INTO |
| | SHOWER STALL AND LINER. |
| | |
| | 3. PER WPB FBC 107.2.1, PROVIDE USABLE SHOWER STALL |
| | DIMENSIONS TO SHOW COMPLIANCE WITH FBC PL 421.4 |
| | |
| | END OF COMMENTS. |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED |
| | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. |
| | |
| | |
| | JERALD SMITH |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | EMAIL [email protected] |
| | MOBILE 561-246-0882 |
| | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND |
| | THURSDAYS |
| | |
| | 21090136 651 OKEECHOBEE BLVD 911 |
| | |