| Plan Review Notes For Permit 21090133 |
| Permit Number |
21090133 |
|
| Review Stop |
G |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2021-10-18 16:51:29 | 1ST REVIEW FBC-2020 RES. | | | PERMIT- 21090133 | | | 10/18/2021 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | | 2020 | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) GAS RISER CORRECTIONS: | | | A) THE PIPING RUN TO THE POOL HEATER AND GAS LOAD ARE | | | MISSING FROM THE REVISED RISER- SECTION 107.2.1 WPB. | | | B) PLEASE ADD THE 60,000 BTU COOKTOP LOAD IN THE GUEST | | | HOUSE TO THE GAS LOAD CALCULATIONS- SECTION G2413.2 FBC | | | RES. | | | C) TWO LOW PRESSURE REGULATORS ARE SHOWN ON THE SAME | | | GAS LINE TO THE GUEST HOUSE. PLEASE REMOVE ONE OF THE | | | REGULATORS- G2421.2. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|