| 2021-09-10 18:09:58 | RESIDENTIAL (R3) RE-ROOF, SECOND BUILDING REVIEW |
| | COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #21090021 |
| | |
| | NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK |
| | SHALL COMPLY WITH THE MATERIALS AND METHODS |
| | REQUIREMENTS IN THE FLORIDA BUILDING CODE. |
| | |
| | 1- PROVIDE COMPLETE PRODUCT APPROVAL AS REQUIRED BY FAC |
| | 61G20-3.001 FOR LOW SLOPE ROOF (FLAT ROOF). THIS WAS |
| | REQUESTED ON PREVIOUS REVIEW BUT IT WAS NOT SUBMITTED. |
| | NOTE: CLEARLY MARK WHICH APPROVED ASSEMBLY IS GOING TO |
| | BE INSTALLED. IF SELECTED ASSEMBLY DOESN'T MEET THE |
| | DESIGN PRESSURES FOR ALL ROOF ZONES AS REQUIRED BY SEC. |
| | R301..2.1 FBC-RESIDENTIAL, THEN SIGNED AND SEALED RAS |
| | 117 CALCULATIONS MAY BE REQUIRED. RAS 117 CALCULATIONS |
| | NEED TO BE SITE SPECIFIC. CALCULATIONS SUBMITTED ARE |
| | FOR ANOTHER JOB: 639 S MANGONIA CIRCLE. ALSO, |
| | CALCULATIONS NEED TO HAVE ENGINEER'S ORIGINAL SEAL AND |
| | SIGNATURE. EITHER SUBMITTED ELECTRONICALLY WITH A |
| | DIGITAL SIGNATURE OR HARD COPY WITH ENGINEER'S ORIGINAL |
| | SEAL/SIGNATURE. |
| | |
| | 2- PROVIDE SPECIFICATIONS SHOWING HOW COMPLYING WITH |
| | THE NEW 2020 CODE REQUIREMENT FOR ROOFING UNDERLAYMENT. |
| | SEC. R905.1.1.1 FBC-RESIDENTIAL. |
| | NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1 |
| | FBC-RESIDENTIAL IS GOING TO BE USED. AND PROVIDE |
| | PRODUCT APPROVAL AS REQUIRED BY F.A.C. 61G20-3.001. |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | |
| | ******************************************************* |
| | ******************************************************* |
| | ************************************************** |
| | ORIGINAL COMMENTS: |
| | |
| | PLAN REVIEW ROOFING |
| | |
| | CHRISTOPHER S. THROOP, C.B.O., CFM |
| | PLANS EXAMINER II PX3169/SFP306 |
| | INSPECTOR BN4338 |
| | BUILDING OFFICIAL BU1635 |
| | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | CITY OF WEST PALM BEACH |
| | (561) 805-6726 |
| | [email protected] |
| | |
| | CODES IN EFFECT: |
| | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | 2017 NEC |
| | |
| | 1ST REVIEW |
| | |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | REF: CONTRACT. SOW INCLUDES PITCHED ROOF (SHINGLES) AND |
| | FLAT ROOF. |
| | |
| | 1. PROVIDE PRODUCT APPROVALS FOR FLAT ROOF. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | 2. PROVIDE PRODUCT APPROVALS (IF REQUIRED) FOR APPROVED |
| | UNDERLAYMENTS. |
| | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |